Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - Tb2 MCCB 85Ka 3P 1250A Electronic Gf & Rc Terminals - S1250GE3AG1250RC

  • TERASAKI
  • BW#: 00847148
  • Mfr#: S1250GE3AG1250RC
  • UNSPSC#: 39121616
Login or Register to view price
QTY

Features
 • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications
 • MCCB sizes available from 16 to 1600A with various common frames and common accessories
 • Customer fit accessories available to enable quick and easy configuration
 • Basic or Advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available
 • The range complies with AS/NZS IEC 60947-2
 • Product Series: TemBreak 2 MCCB
 • Standards Compliance: AS 60947-2 AS/NZS 3947.2 IEC 60947-2
 • Certifications: CE

Specifications

 • Component Type MCCB: AC MCCB
 • Standard Installation Method: Front Connection
 • Trip Unit Protection Type: Electronic
 • Im, Magnetic Trip Current, Max: 15000
 • Im, Magnetic Trip Current, Min: 3125
 • In, Rated Current at 45°C: 1250
 • Ics, Rated Service Short-Circuit Breaking Capacity, 400V AC: 75
 • Ics, Rated Service Short-Circuit Breaking Capacity, 415V AC: 65
 • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 65
 • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 50
 • Ics, Rated Service Short-Circuit Breaking Capacity, 690V AC: 34
 • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 75
 • Icw, Short Time Withstand Current, 300ms (rms): 15
 • Ir, Thermal Trip Current, Max: 1250
 • Ir, Thermal Trip Current, Min: 500
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 125
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400V AC: 100
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 85
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 415V AC: 85
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 85
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 65
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 45
 • Depth: 120
 • Frame Size: 1250 AF
 • Rated Frequency: 50 / 60 Hz
 • Height: 370
 • Number of Poles: 3
 • Electrical Service Life at Un, In: 4000
 • Mechanical service life: 5000
 • Magnetic Trip Type: Selectable
 • Thermal Trip Type: Adjustable
 • Uimp, Impulse Withstand Voltage: 8
 • Ui, Rated Insulation Voltage: 800
 • Un, Nominal Operational Voltage, AC: 690
 • Weight: 19.8
 • Width: 210
 • Reverse Connection Of Supply Possible: Yes

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type MCCB AC
Number of Pole 3
Height 370 mm
Width 210 mm
Weight 19.8 kg
Rated Current 1250 A @45°C
Rated Insulation Voltage 800 V (rms)
Trip Unit Technology Electronic