Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - Tb2 MCCB 70Ka 3P 1000A Electronic With GRound Fault - S1000NE3AG1000

  • TERASAKI
  • BW#: 00846740
  • Mfr#: S1000NE3AG1000
  • UNSPSC#: 39121616
Login or Register to view price
QTY

Features
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications
  • MCCB sizes available from 16 to 1600A with various common frames and common accessories
  • Customer fit accessories available to enable quick and easy configuration
  • Basic or Advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available
  • The range complies with AS/NZS IEC 60947-2
  • Product Series: TemBreak 2 MCCB
  • Standards Compliance: IEC 60947-2 AS 60947-2 AS/NZS 3947.2
  • Certifications: CE


  • Specifications

  • Component Type MCCB: AC MCCB
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Electronic
  • In, Rated Current at 45°C: 1000
  • Ir, Thermal Trip Current, Max: 1000
  • Ir, Thermal Trip Current, Min: 400
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 100
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 70
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 65
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 25
  • Depth: 103
  • Frame Size: 1000 AF
  • Height: 273
  • Number of Poles: 3
  • Electrical Service Life at Un, In: 4000
  • Mechanical service life: 10000
  • Thermal Trip Type: Adjustable
  • Ui, Rated Insulation Voltage: 800
  • Un, Nominal Operational Voltage, AC: 690
  • Weight: 11
  • Width: 210
  • Reverse Connection Of Supply Possible: Yes
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type MCCB AC
    Number of Pole 3
    Height 273 mm
    Width 210 mm
    Weight 11 kg
    Rated Current 1000 A @45°C
    Rated Insulation Voltage 800 V (rms)