Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki ZS125GJ4125 T2 ELCB MCCB - 65KA - 30MA - 3A - 4P - 125A - 112 mm x 136 mm x 168 mm

  • TERASAKI
  • BW#: 00354811
  • Mfr#: ZS125GJ4125
  • UNSPSC#: 39121603
Login or Register to view price
QTY

Features
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications

  • MCCB sizes available from 16 to 1600A with various common frames

  • Basic or advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

  • Service Information: Product is not repairable
  • Product Series: TemBreak 2 ELCB (ZS)
  • Certifications: CE, ASTA
  • Shipping Approvals: Contact NHP
  • Component Type MCCB: MCCB AC
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Adjustable Thermal, Fixed Magnetic
  • Im, Magnetic Trip Current: 1250 A
  • In, Rated Current at 45°C: 125 A @45°C
  • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 25 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 22 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 55 % Icu
  • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 100 % Icu
  • Ir, Thermal Trip Current, Max: 125 A
  • Ir, Thermal Trip Current, Min: 80 A
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 85 kA @220/240VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 65 kA @400/415VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 50 kA @440VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 25 kA @525VAC
  • Depth: 68 mm
  • Frame Size: 125 AF size
  • Rated Frequency: 50/60 Hz
  • Height: 155 mm
  • Number of Poles: 4
  • Poles: 4P
  • Electrical Service Life at Un, In: 10000 cycles
  • Mechanical Service Life: 30000 cycles
  • Earth Leakage Trip Time Type: Selectable time
  • Magnetic Trip Type: Fixed type
  • Thermal Trip Type: Adjustable type
  • Uimp, Impulse Withstand Voltage: 8 kV
  • Ui, Rated Insulation Voltage: 525 V (rms)
  • Ue, Rated Operational Voltage, AC, max: 525 V AC
  • Weight: 1.4 kg
  • Width: 120 mm
  • Reverse Connection Of Supply Possible: Yes
  • Earth Leakage Trip Time Setting Range @IΔn: 0, 60, 200, 400, 700 ms or No trip @IΔn
  • IΔn, Earth Leakage Trip Sensitivity Setting Range: 30mA,100mA, 300mA, 500mA, 1A, 3A
  • IΔn, Earth Leakage Trip Sensitivity Type: Selectable sensitivity
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type MCCB AC
    Number of Pole 4P
    Depth 68 mm
    Width 120 mm
    Height 155 mm
    Size 112x136x168mm
    Colour White
    Weight 1.4 kg
    Customers Also Bought
    Alternate Products