Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - NHP - MCCB - TB2 50KA - 3P 800A Electronic - 200 mm x 310 mm x 530 mm - S800NE3800

  • TERASAKI
  • BW#: 00351989
  • Mfr#: S800NE3800
  • UNSPSC#: 39121603
Login or Register to view price
QTY

Features
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications

  • MCCB sizes available from 16 to 1600A with various common frames

  • Basic or advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

  • Service Information: Product is not repairable
  • Product Series: TemBreak 2 MCCB
  • Standards Compliance: IEC 60947-2, AS 60947-2, AS/NZS 3947.2
  • Certifications: CE
  • Component Type MCCB: MCCB AC
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Electronic
  • In, Rated Current at 45°C: 800 A @45°C
  • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 100 % Icu
  • Icw, Short Time Withstand Current, 300ms (rms): 10 kA, 300ms
  • Ir, Thermal Trip Current, Max: 800 A
  • Ir, Thermal Trip Current, Min: 320 A
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 85 kA @220/240VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 50 kA @400/415VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 50 kA @440VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 20 kA @690VAC
  • Frame Size: 800 AF size
  • Number of Poles: 3
  • Electrical Service Life at Un, In: 4000 cycles
  • Mechanical Service Life: 10000 cycles
  • Thermal Trip Type: Adjustable type
  • Ui, Rated Insulation Voltage: 800 V (rms)
  • Weight: 9.1 kg
  • Width: 210 mm
  • Reverse Connection Of Supply Possible: Yes
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type MCCB AC
    Number of Pole 3P
    Width 210 mm
    Height 200 mm
    Size 200 mm x 310 mm x 530 mm
    Length 530 mm
    Weight 9.1 kg
    Standards Compliance IEC 60947-2, AS 60947-2, AS/NZS 3947.2