Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - NHP - MCCB - TB2 70KA - 3P 250A Electronic - 150 mm x 120 mm x 178 mm - S250PE3250

  • TERASAKI
  • BW#: 00354760
  • Mfr#: S250PE3250
  • UNSPSC#: 39121603
Login or Register to view price
QTY

Features
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications

  • MCCB sizes available from 16 to 1600A with various common frames

  • Basic or advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

 • Service Information: Product is not repairable
 • Product Series: TemBreak 2 MCCB
 • Standards Compliance: IEC 60947-2, AS/NZS 60947-2, EN 60947-2, JIS C 8201-2-1 Ann.1, NEMA AB1
 • Certifications: CE
 • Component Type MCCB: MCCB AC
 • Standard Installation Method: Front Connection
 • Trip Unit Protection Type: Electronic
 • In, Rated Current at 45°C: 250 A @45°C
 • Ir, Thermal Trip Current, Max: 250 A
 • Ir, Thermal Trip Current, Min: 100 A
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 125 kA @220/240VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 70 kA @400/415VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 50 kA @440VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 35 kA @525VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 20 kA @690VAC
 • Depth: 103 mm
 • Frame Size: 250 AF size
 • Height: 165 mm
 • Number of Poles: 3
 • Electrical Service Life at Un, In: 10000 cycles
 • Mechanical Service Life: 30000 cycles
 • Thermal Trip Type: Adjustable type
 • Ui, Rated Insulation Voltage: 800 V (rms)
 • Un, Nominal Operational Voltage, AC: 690 V AC
 • Weight: 2.5 kg
 • Width: 105 mm
 • Reverse Connection Of Supply Possible: Yes

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type MCCB AC
Number of Pole 3P
Voltage Rating 690 V AC
Depth 103 mm
Width 105 mm
Height 165 mm
Size 150x120x178mm
Colour White
Weight 2.5 kg
Standards Compliance IEC 60947-2, AS/NZS 60947-2, EN 60947-2, JIS C 8201-2-1 Ann.1, NEMA AB1