Skip to content Skip to navigation menu
click to open Expanded view

Terasaki - NHP - MCCB - TB2 25KA 3P 50A Thermal Magnetic - 112 mm x 104 mm x 166 mm - E125NJ350

  • TERASAKI
  • BW#: 00354658
  • Mfr#: E125NJ350
  • UNSPSC#: 39121603
Login or Register to view price
QTY

Features
  • D7 pilot devices offer maximum flexibility and a wide choice for all 225mm

  • Operator applications with all type (e-stops, selector switches, pushbuttons, pilot lights and more), colour and contact configurations

  • Aesthetically appealing and modularly designed to make assembly and interchangeability easy

  • Operators exhibit low profile and stylish appearance while maintaining the rugged performance necessary for demanding environments

  • D7P is a plastic operator with a captive black plastic front bezel constructed of high-grade thermoplastics

  • The D7P is suitable for almost all environments and strong chemical resistance

  • D7M has a die-cast zinc housing and mounting ring for rugged durability finished with corrosion resistant chrome plating

  • The D7M also features a captive shiny metal bezel for a polished appearance


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

 • Service Information: Product is not repairable
 • Product Series: TemBreak 2 MCCB
 • Standards Compliance: IEC 60947-2, EN 60947-2, JIS C 8201-2-1 Ann.1, NEMA AB1, AS/NZS 60947-2
 • Certifications: ASTA
 • Shipping Approvals: Contact NHP
 • Component Type MCCB: MCCB AC
 • Standard Installation Method: Front Connection
 • Trip Unit Protection Type: Adjustable Thermal Adjustable Magnetic
 • Im, Magnetic Trip Current, Max: 600 A
 • Im, Magnetic Trip Current, Min: 300 A
 • In, Rated Current at 45°C: 50 A @45°C
 • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 12 kA
 • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 6 kA
 • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 76 % Icu
 • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 76 % Icu
 • Ir, Thermal Trip Current, Max: 50 A
 • Ir, Thermal Trip Current, Min: 32 A
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC: 35 kA @240VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 25 kA @400/415VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 15 kA @440VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 8 kA @525VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 25 kA @250VDC
 • Depth: 68 mm
 • Frame Size: 125 AF size
 • Rated Frequency: 50/60 Hz
 • Height: 155 mm
 • Number of Poles: 3
 • Poles: 3P
 • Electrical Service Life at Un, In: 30000 cycles
 • Mechanical Service Life: 30000 cycles
 • Magnetic Trip Type: Adjustable type
 • Thermal Trip Type: Adjustable type
 • Uimp, Impulse Withstand Voltage: 8 kV
 • Ui, Rated Insulation Voltage: 800 V (rms)
 • Ue, Rated Operational Voltage, AC, max: 525 V AC
 • Ue, Rated Operational Voltage, DC, max: 250 V DC
 • Weight: 1.1 kg
 • Width: 90 mm
 • Reverse Connection Of Supply Possible: Yes

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type MCCB AC
Number of Pole 3P
Depth 68 mm
Width 90 mm
Height 155 mm
Size 112x104x166mm
Weight 1.1 kg
Standards Compliance IEC 60947-2, EN 60947-2, JIS C 8201-2-1 Ann.1, NEMA AB1, AS/NZS 60947-2