Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric TeSys GV4 GV4P115N Motor Circuit breaker - Thermal Magnetic EverLink Terminals - 3P - 115A Icu - 50kA

  • Schneider Electric
  • BW#: 00385768
  • Mfr#: GV4P115N
  • UNSPSC#: 39121601
Login or Register to view price
QTY

Features
  • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
  • GV4 Type P : Magnetic short circuit and overload protection
  • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
  • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
  • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
  • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
  • Ergonomic rotary handle for easy switching and controlling with clear trip indication
  • Other options include: Toggle, side, extended


  • Applications
  • Oil & Gas
  • Wastewater treatment facilities
  • Mining
  • Energy


  • Specifications

    • TeSys GV4, thermal magnetic circuit breaker, 115A 3p, with Everlink

    • Motor Tripping Class - 20

    • Protection Type - overload

    • Range - TeSys

    • [Ics] Rated Service Breaking Capacity - 50 kA - at 440 V AC 50/60 Hz according to IEC 60947-2

    • Product Name - TeSys GV4

    • Breaking Capacity - 65 kA at 208Y/120 V AC 50/60 Hz according to UL 60947

    • Breaking Capacity - [Icu] - 100 kA at 220.240 V AC 50/60 Hz according to IEC 60947-2

    • Breaking Capacity - [Icu] - 15 kA at 525 V AC 50/60 Hz according to IEC 60947-2

    • Poles Description - 3P

    • Product or Component Type - circuit breaker

    • Protection Type - short time short-circuit protection

    • Trip Unit Technology - Thermal-magnetic

    • Utilisation Category - category A

    • Device Application - Motor

    • Protection Type - phase loss

    • [Ics] Rated Service Breaking Capacity - 50 kA - at 380.415 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated Service Breaking Capacity - 15 kA - at 525 V AC 50/60 Hz according to IEC 60947-2

    • Device Short Name - GV4P

    • Breaking Capacity - [Icu] - 50 kA at 380.415 V AC 50/60 Hz according to IEC 60947-2

    • Breaking Capacity - [Icu] - 25 kA at 500 V AC 50/60 Hz according to IEC 60947-2

    • Trip Unit Rating - 65.115 A

    • Control Type - rotary handle

    • Protection Type - ground fault protection

    • Product name - TeSys GV4

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Number of Pole 3P
    Type Circuit Breaker
    Width 81 mm
    Height 155 mm
    Length 155 mm
    Colour Black
    Weight 1600 g
    Trip Unit Technology Electronic
    Thermal-Magnetic
    Air Temperature for Storage -50-85 °C