Skip to content Skip to navigation menu
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric TeSys GV4 GV4P115N Motor Circuit breaker - Thermal Magnetic EverLink Terminals - 3P - 115A Icu - 50kA

  • Schneider Electric
  • BW#: 00385768
  • Mfr#: GV4P115N
  • UNSPSC#: 39121601
Login or Register to view price
QTY

Features
  • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
  • GV4 Type P : Magnetic short circuit and overload protection
  • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
  • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
  • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
  • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
  • Ergonomic rotary handle for easy switching and controlling with clear trip indication
  • Other options include: Toggle, side, extended


  • Applications
  • Oil & Gas
  • Wastewater treatment facilities
  • Mining
  • Energy


  • Specifications

    • TeSys GV4, thermal magnetic circuit breaker, 115A 3p, with Everlink

    • Motor Tripping Class - 20

    • Protection Type - overload

    • Range - TeSys

    • [Ics] Rated Service Breaking Capacity - 50 kA - at 440 V AC 50/60 Hz according to IEC 60947-2

    • Product Name - TeSys GV4

    • Breaking Capacity - 65 kA at 208Y/120 V AC 50/60 Hz according to UL 60947

    • Breaking Capacity - [Icu] - 100 kA at 220.240 V AC 50/60 Hz according to IEC 60947-2

    • Breaking Capacity - [Icu] - 15 kA at 525 V AC 50/60 Hz according to IEC 60947-2

    • Poles Description - 3P

    • Product or Component Type - circuit breaker

    • Protection Type - short time short-circuit protection

    • Trip Unit Technology - Thermal-magnetic

    • Utilisation Category - category A

    • Device Application - Motor

    • Protection Type - phase loss

    • [Ics] Rated Service Breaking Capacity - 50 kA - at 380.415 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated Service Breaking Capacity - 15 kA - at 525 V AC 50/60 Hz according to IEC 60947-2

    • Device Short Name - GV4P

    • Breaking Capacity - [Icu] - 50 kA at 380.415 V AC 50/60 Hz according to IEC 60947-2

    • Breaking Capacity - [Icu] - 25 kA at 500 V AC 50/60 Hz according to IEC 60947-2

    • Trip Unit Rating - 65.115 A

    • Control Type - rotary handle

    • Protection Type - ground fault protection

    • Product name - TeSys GV4

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Number of Pole 3P
    Type Circuit Breaker
    Width 81 mm
    Height 155 mm
    Length 155 mm
    Colour Black
    Weight 1600 g
    Trip Unit Technology Electronic
    Thermal-Magnetic
    Air Temperature for Storage -50-85 °C
    Customers Also Bought
    Alternate Products