Schneider Electric TeSys GV4 GV4P50N Motor Circuit breaker - Thermal Magnetic EverLink Terminals - 3P - 50A Icu - 50kA

  • Schneider Electric
  • BW#: 00387043
  • Mfr#: GV4P50N
  • UNSPSC#: 39121601
Login or Register to view price
QTY

Features
  • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
  • GV4 Type P : Magnetic short circuit and overload protection
  • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
  • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
  • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
  • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
  • Ergonomic rotary handle for easy switching and controlling with clear trip indication
  • Other options include: Toggle, side, extended


  • Applications
  • Oil & Gas
  • Wastewater treatment facilities
  • Mining
  • Energy


  • Specifications

    • TeSys GV4, thermal magnetic circuit breaker, 50A 3p, with Everlink

    • Motor Tripping Class - 10

    • Trip Unit Technology - electronic

    • Utilisation Category - category A

    • Protection Type - phase unbalance

    • [Ics] Rated Service Breaking Capacity - 100 kA - at 220.240 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated Service Breaking Capacity - 25 kA - at 500 V AC 50/60 Hz according to IEC 60947-2

    • Trip Unit Rating - 20.50 A

    • Breaking Capacity - 65 kA at 240 V AC 50/60 Hz according to UL 60947

    • Breaking Capacity - [Icu] - 8 kA at 660.690 V AC 50/60 Hz according to IEC 60947-2

    • Breaking Capacity - [Icu] - 25 kA at 500 V AC 50/60 Hz according to IEC 60947-2

    • Protection Type - short time short-circuit protection

    • Protection Type - overload

    • Device Application - Motor

    • Protection Type - phase loss

    • [Ics] Rated Service Breaking Capacity - 50 kA - at 380.415 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated Service Breaking Capacity - 15 kA - at 525 V AC 50/60 Hz according to IEC 60947-2

    • Device Short Name - GV4P

    • [Ics] Rated Service Breaking Capacity - 2 kA - at 660.690 V AC 50/60 Hz according to IEC 60947-2

    • Breaking Capacity - [Icu] - 100 kA at 220.240 V AC 50/60 Hz according to IEC 60947-2

    • [In] Rated Current - 50 A

    • Poles Description - 3P

    • Product or Component Type - circuit breaker

    • Trip Unit Technology - Thermal-magnetic

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Number of Pole 3P
    Type Circuit Breaker
    Terminal Connection Everlink Btr Screw Connectors (Top) 1 Cable(S) 1.5-70 Mm² - Solid
    Width 81 mm
    Height 155 mm
    Length 155 mm
    Colour Black
    Weight 1600 g
    Trip Unit Technology Electronic
    Thermal-Magnetic
    Air Temperature for Storage -50-85 °C