Schneider Electric TeSys U LUCM32BL Multifunction Control Unit - Motors Protection & Diagnostic - 1P/3P - Class 530 - 8-32A - Coil 24V DC

  • Schneider Electric
  • BW#: 00531254
  • Mfr#: LUCM32BL
  • UNSPSC#: 32150000
Login or Register to view price
QTY

Features
  • Multiple choices for electronic coil: 24 V AC; 24 V DC low consumption; 48-72 V DC/48 V AC; 110-220 V DC/110-240 V AC
  • Short-circuit protection: Isc of 50 kA at 400 V up to 15 kW
  • Overload protection: From 0.15 to 32 A, 6 setting ranges; Test button
  • Reverse starter in 45mm frame only - Different options with plug and play modules: Thermal function management modules; Communication modules; Auxiliary contact add-on modules


  • Applications
  • TeSys U all-in-one motor starter is dedicated to direct on line (including reverser) motor control applications
  • Thanks to the high compactness and outstanding flexibility, it can be well adapted to all types of machines
  • The strong communication capabilities, high breaking capacity and total coordination makes it highly suitable for process application


  • Specifications

  • Multifunction control unit LUCM, class 5 30, 8 32A, 24 V DC
  • Motor power Kw: 15 kW at 400 440 V AC 50/60 Hz
  • Product compatibility: ASILUFC51
  • Product compatibility: LUFC00
  • Product compatibility: LUFN
  • Product compatibility: LULC033
  • Product compatibility: LULC07
  • Product compatibility: LULC09
  • Product compatibility: LULC15
  • Range of product: TeSys U
  • Utilisation category: AC-44
  • Product specific application: Most sophisticated control and protection requirements, with display
  • Thermal overload Class: Class 5…30 - Frequency limit: 50 60 Hz - Temperature compensation: -25 55 °C - Conforming to UL 508
  • [Uc] control circuit voltage: 24 V DC
  • Device short name: LUCM
  • Product compatibility: ASILUFC5
  • Product compatibility: LULC08
  • Utilisation category: AC-41
  • Utilisation category: AC-43
  • Range: TeSys
  • Motor power Kw: 15 kW at 500 V AC 50/60 Hz
  • Product compatibility: LUFV2
  • [Uc] Control Circuit Voltage : 24 V DC
  • [Ue] Rated Operational Voltage : 690 V AC
  • Reset : Automatic Reset - Setting: Setting Range
  • Manual - Setting: Factory Setting
  • Manual - Setting: Setting Range
  • Remote Reset - Setting: Setting Range
  • Resistance To Radiated Fields : 10 V/M 3 Conforming To IEC 61000-4-3
  • Physical Interface : Rs485 Multidrop - Connector(S): Rj45 - Location: Front Panel - Communication Protocol: Modbus Rtu 19200 Bit/S
  • Thermal Protection Adjustment Range : 8-32 A
  • Vibration Resistance : 2 Gn, 5-300 Hz, Power Poles Open Conforming To IEC 60068-2-6
  • 4 Gn, 5-300 Hz, Power Poles Closed Conforming To IEC 60068-2-6
  • Immunity To Microbreaks : 3 Ms
  • Product Name : Tesys Ultra
  • [Uimp] Rated Impulse Withstand Voltage : 6 Kv Conforming To IEC 60947-6-2
  • Standards : EN 60947-6-2
  • IEC 60947-6-2
  • Ul 60947-4-1, With Phase Barrier
  • CSA C22.2 No 60947-4-1, With Phase Barrier
  • Time Before Reset : 1-1000 S - Reset Manual Or Automatic Reset - Setting Settable
  • 120-120 S - Reset Manual - Setting Factory Setting
  • Utilisation Category : AC-43
  • AC-41
  • AC-44
  • [Ui] Rated Insulation Voltage : 690 V Conforming To IEC 60947-6-2
  • 600 V Conforming To Ul 60947-4-1
  • 600 V Conforming To CSA C22.2 No 60947-4-1
  • Messages Display Capacity : 2 Lines Of 12 Characters - Display Lcd - English - Accuracy +/- 5 % - Resolution 1 % Of Ir
  • 2 Lines Of 12 Characters - Display Lcd - French - Accuracy +/- 5 % - Resolution 1 % Of Ir
  • 2 Lines Of 12 Characters - Display Lcd - German - Accuracy +/- 5 % - Resolution 1 % Of Ir
  • 2 Lines Of 12 Characters - Display Lcd - Italian - Accuracy +/- 5 % - Resolution 1 % Of Ir
  • 2 Lines Of 12 Characters - Display Lcd - Spanish - Accuracy +/- 5 % - Resolution 1 % Of Ir
  • Product Specific Application : Most Sophisticated Control And Protection Requirements, With Display
  • User Language : English - Setting Factory Setting
  • English, French, German, Italian, Spanish - Setting Settable
  • Operating Altitude : 2000 M
  • Operating Time : 35 Ms Opening With Lub32 For Control Circuit
  • 35 Ms Opening With Lub38 For Control Circuit
  • 65 Ms Closing With Lub32 For Control Circuit
  • 65 Ms Closing With Lub38 For Control Circuit
  • Depth : 60 mm
  • Immunity To Radioelectric Fields : 10 V Conforming To IEC 61000-4-6
  • Network Frequency : 40...60 Hz
  • Load Type : 3-Phase Motor - Cooling: Self-Cooled - Setting Factory Setting
  • 3-Phase Motor - Cooling: Self-Cooled, Force Cooled - Setting Settable
  • Single-Phase Motor - Cooling: Self-Cooled, Force Cooled - Setting Settable
  • Height : 66 mm
  • Shock Resistance : 10 Gn Power Poles Open Conforming To IEC 60068-2-27
  • 15 Gn Power Poles Closed Conforming To IEC 60068-2-27
  • Immunity To Voltage Dips : 70 % / 500 Ms Conforming To IEC 61000-4-11
  • Motor Power Kw : 15 Kw At 400...440 V Ac 50/60 Hz For 3 Phases Motors
  • 15 Kw At 500 V Ac 50/60 Hz For 3 Phases Motors
  • 18.5 Kw At 690 V Ac 50/60 Hz For 3 Phases Motors
  • 7.5 Kw At 400...440 V Ac 50/60 Hz For 1 Phase Motors
  • Fixing Mode : Plug-In (Front Face)
  • Range : Tesys
  • IP Degree Of Protection : IP20 Front Panel And Wired Terminals Conforming To IEC 60947-1
  • IP20 Other Faces Conforming To IEC 60947-1
  • Ip40 Front Panel Outside Connection Zone Conforming To IEC 60947-1
  • Information Displayed : Average Current (Factory Setting)
  • Average Current (Settable)
  • Cause Of Last 5 Faults (Settable)
  • Current In Phase (Settable)
  • Earth Leakage Current (Settable)
  • Phase Imbalance (Settable)
  • Thermal State Of Motor (Settable)
  • Typical Current Consumption : 220 Ma At 24 V DC I Maximum While Closing With Lub32
  • 220 Ma At 24 V DC I Maximum While Closing With Lub38
  • 80 Ma At 24 V DC I Rms Sealed With Lub32
  • 80 Ma At 24 V DC I Rms Sealed With Lub38
  • Function Available : Manual Or Automatic Reset
  • Monitoring Function, Indication Of Main Motor Parameters
  • Overload, No-Load Running
  • Protection Function Alarm
  • Protection Against Overload And Short-Circuit
  • Protection Against Phase Failure And Phase Imbalance
  • Earth Fault Protection
  • Log Function
  • Differentiation Of Thermal Overload And Magnetic Fault
  • Ambient Air Temperature For Storage : -40-85 °C
  • Tripping Threshold : 14.2 X Ir +/- 20 %
  • Return Time : <= 200 Ms
  • Product Compatibility : Power Base Lub32
  • Power Base Lub38
  • Power Base Lub320
  • Power Base Lub380
  • Reversing Contactor Breaker Lu2B32Fu
  • Reversing Contactor Breaker Lu2B38Fu
  • Protective Treatment : Th Conforming To IEC 60068
  • Resistance To Electrostatic Discharge : 8 Kv Level 3 In Open Air Conforming To IEC 61000-4-2
  • 8 Kv Level 4 On Contact Conforming To IEC 61000-4-2
  • Compatibility Code : Lucm
  • Control Circuit Voltage Limits : 20...28 V For Dc Circuit 24 V In Operation
  • 14.5 V For Dc Circuit 24 V Drop-Out
  • Fire Resistance : 960 °C Parts Supporting Live Components Conforming To IEC 60695-2-12
  • 650 °C Conforming To IEC 60695-2-12
  • Safe Separation Of Circuit : 400 V Selv Between The Control And Auxiliary Circuits Conforming To IEC 60947-1
  • 400 V Selv Between The Control Or Auxiliary Circuit And The Main Circuit Conforming To IEC 60947-1
  • Device Application : Motor Control
  • Motor Protection
  • Resistance To Fast Transients : 2 Kv Class 3 Serial Link Conforming To IEC 61000-4-4
  • 4 Kv Class 4 All Circuits Except For Serial Link Conforming To IEC 61000-4-4
  • Heat Dissipation : 1.8-1.8 W For Control Circuit With Lub32
  • 1.8-1.8 W For Control Circuit With Lub38
  • 0.8-0.8 W For External Auxiliary Circuit
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Multifunction Control Unit
    Certifications CE
    UL
    CSA
    CCC
    EAC
    ASEFA
    ATEX
    Marine
    Height 55 mm
    Length 102 mm
    Width 45 mm
    Colour White
    Weight 0.175 Kg