Features
  • Multiple choices for electronic coil: 24 V AC; 24 V DC low consumption; 48-72 V DC/48 V AC; 110-220 V DC/110-240 V AC
  • Short-circuit protection: Isc of 50 kA at 400 V up to 15 kW
  • Overload protection: From 0.15 to 32 A, 6 setting ranges; Test button
  • Reverse starter in 45mm frame only - Different options with plug and play modules: Thermal function management modules; Communication modules; Auxiliary contact add-on modules


  • Applications
  • TeSys U all-in-one motor starter is dedicated to direct on line (including reverser) motor control applications
  • Thanks to the high compactness and outstanding flexibility, it can be well adapted to all types of machines
  • The strong communication capabilities, high breaking capacity and total coordination makes it highly suitable for process application


  • Specifications

  • Advanced control unit LUCB, Class 10, 3 12A, 110 220 V DC/AC
  • Motor power Kw: 9 kW at 690 V AC 50/60 Hz
  • Device short name: LUCB
  • Product compatibility: LUFDA01
  • Product compatibility: LUFDA10
  • Product compatibility: LUFDH11
  • Range of product: TeSys U
  • Motor power Kw: 5.5 kW at 400 440 V AC 50/60 Hz
  • Motor power Kw: 5.5 kW at 500 V AC 50/60 Hz
  • Product or Component type: Advanced control unit
  • Utilisation category: AC-44
  • Thermal overload class: Class 10 - Frequency limit: 40 60 Hz - Temperature compensation: -25 70 °C - Conforming to IEC 60947-6-2
  • Product name: TeSys U
  • Product compatibility: LUFC00
  • Product compatibility: LUFN
  • Product compatibility: LUFV2
  • [Uc] control circuit voltage: 110 220 V DC
  • [Uc] control circuit voltage: 110 240 V AC
  • Product compatibility: LUFW10
  • Thermal protection adjustment range: 3 12 A
  • Utilisation category: AC-41
  • Utilisation category: AC-43
  • [Uc] Control Circuit Voltage : 110...240 V AC
  • 110...220 V DC
  • Height : 66 mm
  • [Ue] Rated Operational Voltage : 690 V AC
  • Range Of Product : Tesys Ultra
  • Reset : Manual Reset
  • Resistance To Radiated Fields : 10 V/M 3 Conforming To IEC 61000-4-3
  • Phase Failure Sensitivity : Yes
  • Thermal Protection Adjustment Range : 3-12 A
  • Non-Dissipating Shock Wave : 1 Kv Serial Mode Conforming To IEC 60947-6-2
  • 2 Kv Common Mode Conforming To IEC 60947-6-2
  • Shock Resistance : 10 Gn Power Poles Open Conforming To IEC 60068-2-27
  • 15 Gn Power Poles Closed Conforming To IEC 60068-2-27
  • Vibration Resistance : 2 Gn, 5-300 Hz, Power Poles Open Conforming To IEC 60068-2-6
  • 4 Gn, 5-300 Hz, Power Poles Closed Conforming To IEC 60068-2-6
  • Immunity To Microbreaks : 3 Ms
  • Immunity To Voltage Dips : 70 % / 500 Ms Conforming To IEC 61000-4-11
  • Product Name : Tesys Ultra
  • Thermal Overload Class : Class 10 - Frequency Limit: 40-60 Hz - Temperature Compensation:25-70 °C Conforming To IEC 60947-6-2
  • Class 10 - Frequency Limit: 40-60 Hz - Temperature Compensation:25-70 °C Conforming To Ul 508
  • Motor Power Kw : 5.5 kW At 400...440 V AC 50/60 Hz
  • 5.5 kW At 500 V AC 50/60 Hz
  • 9 kW At 690 V AC 50/60 Hz
  • Fixing Mode : Plug-In (Front Face)
  • [Uimp] Rated Impulse Withstand Voltage : 6 Kv Conforming To IEC 60947-6-2
  • Range : Tesys
  • IP Degree Of Protection : IP20 Front Panel And Wired Terminals Conforming To IEC 60947-1
  • IP20 Other Faces Conforming To IEC 60947-1
  • Ip40 Front Panel Outside Connection Zone Conforming To IEC 60947-1
  • Standards : EN 60947-6-2
  • IEC 60947-6-2
  • Ul 60947-4-1, With Phase Barrier
  • CSA C22.2 No 60947-4-1, With Phase Barrier
  • Utilisation Category : AC-43
  • AC-44
  • AC-41
  • Typical Current Consumption : 280 Ma At 110...240 V AC I Maximum While Closing With Lub12
  • 280 Ma At 110...240 V AC I Maximum While Closing With Lub32
  • 280 Ma At 110...240 V AC I Maximum While Closing With Lub38
  • 280 Ma At 110...220 V DC I Maximum While Closing With Lub12
  • 280 Ma At 110...220 V DC I Maximum While Closing With Lub32
  • 280 Ma At 110...220 V DC I Maximum While Closing With Lub38
  • 35 Ma At 110...240 V AC I Rms Sealed With Lub12
  • 25 Ma At 110...240 V AC I Rms Sealed With Lub32
  • 25 Ma At 110...240 V AC I Rms Sealed With Lub38
  • 35 Ma At 110...220 V DC I Rms Sealed With Lub12
  • 25 Ma At 110...220 V DC I Rms Sealed With Lub32
  • 25 Ma At 110...220 V DC I Rms Sealed With Lub38
  • Function Available : Earth Fault Protection
  • Protection Against Phase Failure And Phase Imbalance
  • Protection Against Overload And Short-Circuit
  • Manual Reset
  • [Ui] Rated Insulation Voltage : 690 V Conforming To IEC 60947-6-2
  • 600 V Conforming To Ul 60947-4-1
  • 600 V Conforming To CSA C22.2 No 60947-4-1
  • Ambient Air Temperature For Storage : -40-85 °C
  • Tripping Threshold : 14.2 X Ir +/- 20 %
  • Product Compatibility : Power Base Lub12
  • Power Base Lub32
  • Power Base Lub38
  • Power Base Lub120
  • Power Base Lub320
  • Power Base Lub380
  • Reversing Contactor Breaker Lu2B12Fu
  • Reversing Contactor Breaker Lu2B32Fu
  • Reversing Contactor Breaker Lu2B38Fu
  • Product Specific Application : Basic Protection And Advanced Functions, Communication
  • Protective Treatment : Th Conforming To IEC 60068
  • Resistance To Electrostatic Discharge : 8 Kv Level 3 In Open Air Conforming To IEC 61000-4-2
  • 8 Kv Level 4 On Contact Conforming To IEC 61000-4-2
  • Operating Altitude : 2000 M
  • Control Circuit Voltage Limits : 88...264 V For AC Circuit 110...240 V In Operation
  • 88...242 V For Dc Circuit 110...220 V In Operation
  • 55 V For Ac Circuit 110...240 V Drop-Out
  • 55 V For Dc Circuit 110...220 V Drop-Out
  • Operating Time : 35 Ms Opening With Lub12 For Control Circuit
  • 35 Ms Opening With Lub32 For Control Circuit
  • 35 Ms Opening With Lub38 For Control Circuit
  • 50 Ms Closing With Lub12 For Control Circuit
  • 50 Ms Closing With Lub32 For Control Circuit
  • 50 Ms Closing With Lub38 For Control Circuit
  • Fire Resistance : 960 °C Parts Supporting Live Components Conforming To IEC 60695-2-12
  • 650 °C Conforming To IEC 60695-2-12
  • Safe Separation Of Circuit : 400 V Selv Between The Control And Auxiliary Circuits Conforming To IEC 60947-1
  • 400 V Selv Between The Control Or Auxiliary Circuit And The Main Circuit Conforming To IEC 60947-1
  • Depth : 60 mm
  • Immunity To Radioelectric Fields : 10 V Conforming To IEC 61000-4-6
  • Network Frequency : 40...60 Hz
  • Device Application : Motor Control
  • Motor Protection
  • Load Type : 3-Phase Motor - Cooling: Self-Cooled
  • Device Short Name : Lucb
  • Resistance To Fast Transients : 2 Kv Class 3 Serial Link Conforming To IEC 61000-4-4
  • 4 Kv Class 4 All Circuits Except For Serial Link Conforming To IEC 61000-4-4
  • Heat Dissipation : 2-2 W For Control Circuit With Lub12
  • 3-3 W For Control Circuit With Lub32
  • 3-3 W For Control Circuit With Lub38
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Advanced Control Unit
    Certifications CE
    UL
    CSA
    CCC
    EAC
    ASEFA
    ATEX
    Marine
    Height 103 mm
    Length 80 mm
    Width 45 mm
    Weight 127 g