Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Vigirex 56274 Residual Current Protection Relay - RH99P - Front Panel Mounting - 30mA To 30A - 380/415V AC - 50/60Hz

  • Schneider Electric
  • BW#: 00799106
  • Mfr#: 56274
  • UNSPSC#: 39121032
Login or Register to view price
QTY

Features
  • Protection: when detecting significant leakage current in the line it monitors, the relay trips the breaker at the top end of it, through its shunt trip auxiliary
  • Monitoring: signalling leakage current by LED, bargraph or digital display on front, and by an output dry contact. Available in single-line and multi-line variants monitoring up to 12 different distribution lines.
  • Residual current sensitivity ranging from 30 mA to 30 A, fixed or adjustable, for A type relays,
    and 30 mA to 3 A for B type relays
  • Trip time delay ranging from 0 to 4.5 seconds, fixed or adjustable
    o Networks with operating voltage up to 1000 V, and frequency up to 400 Hz
    o lines with current carrying capacity up to 3200 A
    o main switchboards (at the foot of the transformer) in most demanding industrial environments (overvoltage withstand category IV)
  • Type A or type B as per IEC 60 755
  • Compliant with standards:
    o IEC 60 755 and IEC 60947-2 appendix M (certificates by Kema laboratories available)
    o UL 1053 listed, CSA C22.2 N° 144 for North-America
    o EAC for Russia, CCC for China
  • DIN profile, to clip on rail or secure on backplate
  • 72x72mm, for switchboard front plate or door mounting, using clips
    o Closed toroids; for new installations (new switchboards or extensions), with cable capacity up to 630 A for A type relays, 250 A for B type relays
    o Rectangular sensors; for lines with capacity up to 3200 A (busbars, or cables above 630 A)
    o Split toroids; to equip distribution lines already in operation, with cable capacity up to 250 A


  • Applications
  • Electrical networks operating with voltage above 500 V (up to 1000) or frequency higher than 60 Hz (up to 400)
  • Distribution lines with capacity 630 A and above (up to 3200)
  • Upgrade of switchboards already in operation
  • Monitoring and protection at the root of power distribution
  • Three-phase supplied loads including rectifiers : lifts, cranes, HVAC, high-power speed drives, UPS...
  • Single-phase DC boost power supply in some electric vehicle chargers
  • Loads including single-phase speed drives: washing machines, air-conditioning units, heat pumps, food processors)
  • power supply network equipped with harmonic filters


  • Specifications

     • Range : Vigirex
     • Range of product : Vigirex
     • Range compatibility : Vigirex RH TOA earth leakage current sensor
     • Range compatibility : Vigirex RH A earth leakage current sensor
     • Relay application : Residual current protection relay
     • Product or component type : Residual current protection relay
     • Device short name : RH99P
     • Ik Degree Of Protection : Ik07 Conforming To EN 50102
     • Type Of Setting : Selector
     • Reset : Manual Reset
     • Mechanical Robustness : Fire ResistanCE Conforming To IEC 60695-2-1
     • Ik Protection 2 Joules: Ik07 Conforming To EN 50102
     • Vibrations 13.2...100 Hz: 0.7 G
     • Vibrations 2...13.2 Hz: +/- 1 mm
     • Earth Leakage Current : 0.03-30 A
     • Height : 72 mm
     • Ambient Air Temperature For Operation : -35-70 °C
     • Earth-Leakage Protection Class : Type A
     • Type Of Measurement : Earth Fault Current Internal Measurement, Range: 80...100 %
     • Network Rated Voltage : 1000-1000 V - Ac At 50/60 Hz (Maximum)
     • 1000-1000 V - Ac At 400 Hz (Maximum)
     • [Ithe] Conventional Enclosed Thermal Current : 8 A
     • Earthing System : Tn-S
     • Tt
     • It
     • Relay Application : Protection Relay
     • Electromagnetic Compatibility : Conducted And Radiated Emissions: , B, Conforming To Cispr 11
     • Conducted Radio-Frequency Immunity Test: , 3, Conforming To IEC 61000-4-6
     • Electrostatic Discharge Immunity Test: , 4, Conforming To IEC 61000-4-2
     • High-Energy Conducted Susceptibility: , 4, Conforming To IEC 61000-4-5
     • Low-Energy Conducted Susceptibility: , 4, Conforming To IEC 61000-4-4
     • Radiated Susceptibility: , 3, Conforming To IEC 61000-4-3
     • Net Weight : 0.3 Kg
     • Tamperproof Of Settings : Protected By Sealable Cover
     • Range : Vigipact
     • Wire Stripping Length : Auxiliary Power Supply: 7 mm
     • Fault: 7 mm
     • Relay Test And Fault Reset: 7 mm
     • Sensor: 7 mm
     • Voltage Presence: 7 mm
     • Residual Earth-Leakage Time Delay Adjustment Type : Instantaneous For 0.03-0.03 A
     • Adjustable 9 Settings 0-4.5 S For 0.03-30 A
     • Connections - Terminals : Auxiliary Power Supply: Terminal Block Cable(S) 0.2-2.5 mm² Flexible Awg 24...Awg 12
     • Auxiliary Power Supply: Terminal Block Cable(S) 0.2-2.5 mm² Rigid Awg 24...Awg 12
     • Auxiliary Power Supply: Terminal Block Cable(S) 0.25-2.5 mm² Flexible Awg 24...Awg 12
     • Fault: Terminal Block Cable(S) 0.2-2.5 mm² Flexible Awg 24...Awg 12
     • Fault: Terminal Block Cable(S) 0.2-2.5 mm² Rigid Awg 24...Awg 12
     • Fault: Terminal Block Cable(S) 0.25-2.5 mm² Flexible Awg 24...Awg 12
     • Relay Test And Fault Reset: Terminal Block Cable(S) 0.2-2.5 mm² Flexible Awg 24...Awg 12
     • Relay Test And Fault Reset: Terminal Block Cable(S) 0.2-2.5 mm² Rigid Awg 24...Awg 12
     • Relay Test And Fault Reset: Terminal Block Cable(S) 0.25-2.5 mm² Flexible Awg 24...Awg 12
     • Sensor: Terminal Block Cable(S) 0.2-2.5 mm² Flexible Awg 24...Awg 12
     • Sensor: Terminal Block Cable(S) 0.2-2.5 mm² Rigid Awg 24...Awg 12
     • Sensor: Terminal Block Cable(S) 0.25-2.5 mm² Flexible Awg 24...Awg 12
     • Voltage Presence: Terminal Block Cable(S) 0.2-2.5 mm² Flexible Awg 24...Awg 12
     • Voltage Presence: Terminal Block Cable(S) 0.2-2.5 mm² Rigid Awg 24...Awg 12
     • Voltage Presence: Terminal Block Cable(S) 0.25-2.5 mm² Flexible Awg 24...Awg 12
     • Residual Earth-Leakage Sensitity Adjustment Type : Adjustable 9 Settings
     • Power Consumption In VA : 4 Va
     • [Us] Rated Supply Voltage : 380...415 V AC 50/60 Hz 55...110 %
     • Pollution Degree : 3 Conforming To IEC 60664-1
     • Cut-Out Dimensions : 68 X 68 mm
     • Ambient Air Temperature For Storage : -55-85 °C
     • Relative Humidity : 95-95 % At 55-55 °C
     • IP Degree Of Protection : Ip40 On Front Face: Conforming To EN/IEC60529
     • Ip30 On Side Parts: Conforming To EN/IEC60529
     • IP20 On Connection Terminals: Conforming To EN/IEC60529
     • Compatibility Code : Rh99P
     • Test Function : Remote Test
     • Local
     • Electrical Shock Protection Class : Class Ii
     • Monitoring : Electronics (Continuous)
     • Power Supply (Continuous)
     • Relay/Sensor Link (Continuous)
     • [Uimp] Rated Impulse Withstand Voltage : 8 Kv
     • Width : 72 mm
     • Overvoltage Category : Iv
     • Depth : 78 mm
     • Tightening Torque : Auxiliary Power Supply: 0.6-0.6 N.M
     • Fault: 0.6-0.6 N.M
     • Relay Test And Fault Reset: 0.6-0.6 N.M
     • Sensor: 0.6-0.6 N.M
     • Voltage Presence: 0.6-0.6 N.M
     • Minimum Load : 10 Ma At 12 V

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Residual Current Protection Relay
    Frequency Rating 50/60Hz
    Current Rating 30mA To 30A
    Mounting Type Front Panel
    Colour Black