Features
and 30 mA to 3 A for B type relays
o Networks with operating voltage up to 1000 V, and frequency up to 400 Hz
o lines with current carrying capacity up to 3200 A
o main switchboards (at the foot of the transformer) in most demanding industrial environments (overvoltage withstand category IV)
o IEC 60 755 and IEC 60947-2 appendix M (certificates by Kema laboratories available)
o UL 1053 listed, CSA C22.2 N° 144 for North-America
o EAC for Russia, CCC for China
o Closed toroids; for new installations (new switchboards or extensions), with cable capacity up to 630 A for A type relays, 250 A for B type relays
o Rectangular sensors; for lines with capacity up to 3200 A (busbars, or cables above 630 A)
o Split toroids; to equip distribution lines already in operation, with cable capacity up to 250 A
Applications
Specifications
• [Ie] rated operational current: 160 A
• Product or Component type: Earth leakage current sensor
• Range: Vigirex
• Device application: Equipment monitoring and control
• Device short name: IA80
• Range compatibility: Vigirex RH Plug-in relay
• Product Certifications : CE
• Mounting Mode : Fixed (Cables)
• Fixed (Plain Backplate)
• Fixed (Profiled Sheet Metal)
• Fixed (Slotted Backplate)
• Clip-On (Din Rail)
• Network Frequency : 45...440 Hz
• Height : 122 mm
• Ambient Air Temperature For Operation : -35-70 °C
• Residual Short-Circuit Withstand Current : 85 Ka / 0.5 S Conforming To IEC 60947-2
• Standards : IEC 60947-2
• [Uimp] Rated Impulse Withstand Voltage : 12 Kv
• Network Type : AC/DC
• Range Compatibility : Rh10M Residual Current Protection Relay
• Rh10P Residual Current Protection Relay
• Rh21M Residual Current Protection Relay
• Rh21P Residual Current Protection Relay
• Rh68M Residual Current Protection Relay
• Rh86M Residual Current Protection Relay
• Rh86P Residual Current Protection Relay
• Rh99M Residual Current Protection Relay
• Rh99P Residual Current Protection Relay
• Rh197M Residual Current Protection Relay
• Rh197P Residual Current Protection Relay
• Rhu Residual Current Protection Relay
• Rhus Residual Current Protection Relay
• Rmh Residual Current Protection Relay
• [Ui] Rated Insulation Voltage : 1000 V
• Environmental Characteristic : Exposure To Damp Heat Not In Service (25...55 °C, Rh 95 %) : 28 Cycles Conforming To IEC 60068-2-30
• Salt Mist: Kb/2 Conforming To IEC 60068-2-52
• Exposure To Damp Heat In Service: Category C2: 48 Hours Conforming To IEC 60068-2-56
• Connections - Terminals : Screw Connection 0.22-0.22 mm²
• Net Weight : 0.42 Kg
• Range : Vigipact
• Cable Outer Diameter : 40-40 mm: 95-95 mm² (Maximum)
• Pollution Degree : Level 3 Conforming To IEC 60664-1
• Ambient Air Temperature For Storage : -55-85 °C
• Calorific Value : 3.19 Mj
• Compatibility Code : IA80
• IP Degree Of Protection : Connectors: IP20
• IP30
• Current Transformer Type : A Type Closed Toroid
• Width : 150 mm
• Market Segment : Residential
• Small Commercial
• Overvoltage Category : Iv
• Depth : 44 mm
• [Icw] Rated Short-Time Withstand Current : 100 Ka For 0.5 S
• Diameter : 80 mm Inner
• Transformer Ratio : 1/1000