Sun Hydraulics Counterbalance Valve - Vented - Atmospherically Referenced - 5:1 Pilot Ratio - CACGLGN

  • Sun Hydraulics
  • BW#: 02994826
  • Mfr#: CACGLGN
  • UNSPSC#: 40141608
Login or Register to view price
QTY

Features
  • Atmospherically vented counterbalance valves with pilot assist are meant to control an overrunning load

  • The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2

  • Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio

  • Backpressure at port 2 does not affect the valve setting because the spring chamber is atmospherically referenced

  • Other names for this valve include motion control valve and over-center valve

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure

  • Turn adjustment clockwise to decrease setting and release load

  • Full clockwise setting is 200 psi (14 bar)

  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles

  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages

  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals

  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit

  • This valve has positive seals between all ports

  • With vented valves, a lower pilot ratio may be required to achieve machine stability compared to non-vented valves

  • Three-port vented valves are atmospherically referenced and considered problem solvers for existing circuits using non-vented valves. Over time, the vented valves may leak externally or allow moisture into the spring chamber

  • Four-port vented counterbalance valves are recommended for new applications

  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size)

  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations


Specifications

  • Cavity : T-11A

  • Series : 1

  • Capacity : 15 gpm

  • Pilot Ratio : 5:1

  • Maximum Recommended Load Pressure at Maximum Setting : 4615 psi

  • Maximum Setting : 6000 psi

  • Factory Pressure Settings Established at : 2 in³/min.

  • Maximum Valve Leakage at Reseat : 5 drops/min.

  • Check Cracking Pressure : 40 psi

  • Adjustment - No. of CCW Turns from Min. to Max. Setting : 5

  • Operating Characteristic : Standard

  • Reseat : >85% of setting

  • Valve Hex Size : 7/8 in.

  • Valve Installation Torque : 30 - 35 lbf ft

  • Adjustment Screw Internal Hex Size : 5/32 in.

  • Locknut Hex Size : 9/16 in.

  • Locknut Torque : 80 - 90 lbf in.

  • Model Weight : 0.44 lb.

  • Seal kit - Cartridge : 990211007

  • Seal kit - Cartridge : 990011014

  • Seal kit - Cartridge : 990211006