Features
  • Maximum 15 current ratings to cover from 0.1 A to 32 A motor current with a IP20 level for finger safety
  • The electrical durability (AC-3/415 V) can reach 100,000 operations as a direct control switch
  • Screw clamp for the connection, GV2 ME has two more choices: lug and spring terminals
  • Padlockable in all versions
  • DIN rail mounting or screw fixing
  • Multiple choices for "add-on blocks" and accessories such as: contact blocks, electric trips blocks and limiter blocks


  • Applications
  • TeSys GV2 can be used for all type of applications across industry, infrastructure and buildings
  • Compliant to Motor control and protection, in accordance with standards IEC 60947-2, IEC 60947-4-1 and UL 60947-4-1 (transition from UL 508)
  • GV2RT can be used to protect motors with high current peak on starting or transformer protection


  • Specifications

     • Product Certifications : CCC
     • Ul
     • CSA
     • EAC
     • Atex
     • Bv
     • Lros (Lloyds Register Of Shipping)
     • UKCA
     • Dnv-Gl
     • Rina
     • [In] Rated Current : 6.3 A
     • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz Conforming To IEC 60947-2
     • Standards : EN/IEC60947-2
     • EN/IEC60947-4-1
     • Rated Duty : Continuous Conforming To IEC 60947-4-1
     • Network Type : AC
     • [Ith] Conventional Free Air Thermal Current : 6.3 A Conforming To IEC 60947-4-1
     • Motor Power Kw : 2.2-2.2 Kw At 400/415 V AC 50/60 Hz
     • 3-3 Kw At 500 V AC 50/60 Hz
     • 4-4 Kw At 690 V AC 50/60 Hz
     • Operating Position : Any Position
     • Product Name : Tesys Gv2
     • Tesys Deca
     • Utilisation Category : Ac-3 Conforming To IEC 60947-4-1
     • Category A Conforming To IEC 60947-2
     • Net Weight : 0.26 Kg
     • [Uimp] Rated Impulse Withstand Voltage : 6 Kv Conforming To IEC 60947-2
     • [Ui] Rated Insulation Voltage : 690 V AC 50/60 Hz Conforming To IEC 60947-2
     • Direct Connector : Without
     • Poles Description : 3P
     • Operating Altitude : 2000 M
     • Depth : 78.5 mm
     • Network Frequency : 50/60 Hz Conforming To IEC 60947-4-1
     • Trip Unit Technology : Thermal-Magnetic
     • Ik Degree Of Protection : Ik04
     • Ambient Air Temperature For Operation : -20-60 °C
     • Height : 89 mm
     • Range Of Product : Tesys Gv2
     • Phase Failure Sensitivity : Yes Conforming To IEC 60947-4-1
     • Magnetic Tripping Current : 78-78 A
     • Maximum Operating Rate : 25 Cyc/H
     • Fixing Mode : 35 mm Symmetrical Din Rail: Clipped
     • Panel: Screwed (With Adaptor Plate)
     • Range : Tesys
     • Tesys Deca
     • [Ics] Rated Service Short-Circuit Breaking Capacity : 100 % At 500 V AC 50/60 Hz Conforming To IEC 60947-2
     • 100 % At 230/240 V AC 50/60 Hz Conforming To IEC 60947-2
     • 100 % At 440 V AC 50/60 Hz Conforming To IEC 60947-2
     • 100 % At 400/415 V AC 50/60 Hz Conforming To IEC 60947-2
     • 75 % At 690 V AC 50/60 Hz Conforming To IEC 60947-2
     • Control Type : Push-Button
     • Power Dissipation Per Pole : 2.5 W
     • Electrical Durability : 100000 Cycles For Ac-3 At 415 V
     • At 415 V
     • Breaking Capacity : 100 Ka Icu At 230/240 V AC 50/60 Hz Conforming To IEC 60947-2
     • 100 Ka Icu At 400/415 V AC 50/60 Hz Conforming To IEC 60947-2
     • 3 Ka Icu At 690 V AC 50/60 Hz Conforming To IEC 60947-2
     • 50 Ka Icu At 440 V AC 50/60 Hz Conforming To IEC 60947-2
     • 50 Ka Icu At 500 V AC 50/60 Hz Conforming To IEC 60947-2
     • Ambient Air Temperature For Storage : -40-80 °C
     • Suitability For Isolation : Yes Conforming To IEC 60947-1
     • Trip Unit Rating : 4-6.3 A
     • Tightening Torque : 1.7 N.M On Screw Clamp Terminals
     • IP Degree Of Protection : IP20 Conforming To IEC 60529
     • Mechanical Durability : 100000 Cycles
     • Compatibility Code : Gv2Me
     • Fire Resistance : 960 °C Conforming To IEC 60695-2-1
     • Device Application : Motor
     • Device Short Name : Gv2Me