Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric A9L20600 Acti 9 iPF K IPRD20 Modular Surge Arrester - 3P + N - 350V

  • Schneider Electric
  • BW#: 03307065
  • Mfr#: A9L20600
  • UNSPSC#: 39121610
Login or Register to view price
QTY

Features
  • Acti9 iPRD Type 2 and 3 modular Surge Protection Devices protect the electrical equipments against the indirect lightning strikes
  • With exclusive features, Acti9 iPRD DIN rail Surge Protection Devices are geared to protect your equipments from indirect lightning strikes and improve the continuity of service
  • Withdrawable cartridges of Acti9 iPRD Surge arresters allow quick replacement of damaged devices
  • The Acti9 iPRD surge arresters "r" version have dry contacts for transfering remotely the end-of-life information
  • The Acti9 iPRD8 Type 3 is placed in cascade near the loads to be protected
  • They should be installed in the secondary panel board, as soon as the distance from the incoming surge arrester is more than 10 meters, to ensure secondary protection
  • In a building with a height greater than 10 meters, with several dwellings, if a Type 1 surge arrester is installed in the main electrical switchboard, a Type 2 surge arrester must also be installed at the head of each divisional switchboards in order to distribute the constraints


  • Applications
  • The use of Surge Protection Devices is recommended in the case of non-critical power installations
  • It is possible to use multipolar or unipolar products for serial assembly


  • Specifications

  • They are tested and rated according to the standardised current wave of 8/20 µs
  • Certified for short-circuit current withstand, Isc up to 50 kA (IEC 61643-11: 2011)
  • The maximum discharge current covers from 8 to 65 kA
  • The maximum continuous operating voltage Uc is 350 VAC or 460 VAC
  • They are suitable for any earthing system: TT, TN-S, TN-C and IT
  • In every new house without a lightning rod (primary protection) it is now mandatory to install in the electrical switchboard a Type 2 Surge Protection Device to reach the IEC 61643-11: 2011 standard
  • This complementarity of the protections is mandatory to meet the IEC 61643-11: 2011 standard
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Customers Also Bought