Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki ZS125GJ363 T2 ELCB MCCB - 65kA - 30mA - 6.3A - 3P - 63A

  • TERASAKI
  • BW#: 00639663
  • Mfr#: ZS125GJ363
  • UNSPSC#: 39121616
Login or Register to view price
QTY

Features
  • MCCB sizes available from 16 to 1600A with various common frames and common accessories

  • Customer fit accessories available to enable quick and easy configuration

  • Basic or advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available


Applications
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications


Specifications

  • Component type MCCB : AC MCCB

  • Standard installation method : Front connection

  • Trip unit protection type : Adjustable thermal, Fixed magnetic

  • Im, magnetic trip current : 756

  • In, rated current at 45°C : 63

  • Ics, rated service short-circuit breaking capacity, 440V AC : 25

  • Ics, rated service short-circuit breaking capacity, 525V AC : 22

  • Ics, rated service short-circuit breaking capacity, AC (IEC 60947) : 55

  • Ics, rated service short-circuit breaking capacity, DC : 100

  • Ir, thermal trip current, max : 63

  • Ir, thermal trip current, min : 40

  • IΔn, earth leakage trip sensitivity setting range : 30mA,100mA, 300mA, 500mA, 1A, 3A

  • Icu, rated ultimate short-circuit breaking capacity, 220/240V AC : 85

  • Icu, rated ultimate short-circuit breaking capacity, 400/415V AC : 65

  • Icu, rated ultimate short-circuit breaking capacity, 440V AC : 50

  • Icu, rated ultimate short-circuit breaking capacity, 525V AC : 25

  • Depth : 68

  • Frame size : 125 AF

  • Rated frequency : 50 / 60 Hz

  • Height : 155

  • Number of poles : 3

  • Poles : 3P

  • Electrical service life at Un, In : 10000

  • Mechanical service life : 30000

  • Earth leakage trip time setting range @IΔn : 0, 60, 200, 400, 700 ms or no trip

  • IΔn, earth leakage trip sensitivity type : Selectable

  • Earth leakage trip time type : Selectable

  • Magnetic trip type : Fixed

  • Thermal trip type : Adjustable

  • Uimp, impulse withstand voltage : 8

  • Ui, rated insulation voltage : 525

  • Ue, rated operational voltage, AC, max : 525

  • Weight : 1.1

  • Width : 90

  • Reverse connection of supply possible : Yes

  • The range complies with AS/NZS IEC 60947-2

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type MCCB AC
Number of Pole 3
Height 155 mm
Width 90 mm
Weight 1.1 kg
Rated Current 63 A @45°C
Rated Insulation Voltage 525 V (rms)
Trip Unit Technology Adjustable Thermal, Fixed Magnetic