Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - Tb2 MCCB Lite 40Ka 4P 250A - S250SJ4250

  • TERASAKI
  • BW#: 00814253
  • Mfr#: S250SJ4250
  • UNSPSC#: 39121616
Login or Register to view price
QTY



Specifications

 • Service Information: Product is not repairable
 • Product Series: TemBreak 2 MCCB
 • Standards Compliance: AS 60947-2, AS/NZS 3947.2, IEC 60947-1, IEC 60947-2, JIS C 8201-2-1 Ann.1, NEMA AB1
 • Certifications: CE
 • Component Type MCCB: MCCB AC
 • Standard Installation Method: Front Connection
 • Trip Unit Protection Type: Adjustable Thermal Adjustable Magnetic
 • Colour, Body/Housing: Grey colour
 • In, Rated Current at 45°C: 250 A @45°C
 • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 50 % Icu
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 85 kA @220/240VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 40 kA @400/415VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 40 kA @440VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 4 kA @690VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 25 kA @250VDC
 • Depth: 68 mm
 • Frame Size: 250 AF size
 • Height: 165 mm
 • Number of Poles: 4
 • Electrical Service Life at Un, In: 10000 cycles
 • Mechanical Service Life: 20000 cycles
 • Magnetic Trip Type: Adjustable type
 • Thermal Trip Type: Adjustable type
 • Ui, Rated Insulation Voltage: 690 V (rms)
 • Un, Nominal Operational Voltage, AC: 690 V AC
 • Weight: 1.9 kg
 • Width: 140 mm
 • Reverse Connection Of Supply Possible: Yes

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type MCCB AC
Number of Pole 4
Height 165 mm
Width 140 mm
Weight 1.9 kg
Rated Current 250 A @45°C
Rated Insulation Voltage 690 V (rms)
Trip Unit Technology Adjustable Thermal Adjustable Magnetic
Customers Also Bought
Alternate Products