Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - Tb2 MCCB Lite 40Ka 3P 125A With Tunnel Terminals - S160SJ3125FW

  • TERASAKI
  • BW#: 00813199
  • Mfr#: S160SJ3125FW
  • UNSPSC#: 39121616
Login or Register to view price
QTY



Specifications

 • Product Series: TemBreak 2 MCCB
 • Standards Compliance: AS 60947-2, AS/NZS 3947.2, IEC 60947-1, IEC 60947-2, JIS C 8201-2-1 Ann.1, NEMA AB1
 • Certifications: CE
 • Component Type MCCB: MCCB AC
 • Standard Installation Method: Front Connection
 • Trip Unit Protection Type: Adjustable Thermal, Fixed Magnetic
 • Im, Magnetic Trip Current: 1500 A
 • In, Rated Current at 45°C: 125 A @45°C
 • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 13 kA
 • Ics, Rated Service Short-Circuit Breaking Capacity, 500V AC: 7.5 kA
 • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 7.5 kA
 • Ics, Rated Service Short-Circuit Breaking Capacity, 690V AC: 3 kA @690VAC
 • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 50 % Icu
 • Ir, Thermal Trip Current, Max: 125 A
 • Ir, Thermal Trip Current, Min: 80 A
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 50 kA @220/240VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC: 50 kA @240VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 40 kA @400/415VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 25 kA @440VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 500V AC: 10 kA @500VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 10 kA @525VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 125V DC: 35 kA @125VDC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 25 kA @250VDC
 • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 500V DC: 10 kA @500VDC
 • Depth: 68 mm
 • Frame Size: 160 AF size
 • Rated Frequency: 50/60 Hz
 • Height: 130 mm
 • Number of Poles: 3
 • Electrical Service Life at Un, In: 10000 cycles
 • Mechanical Service Life: 20000 cycles
 • Magnetic Trip Type: Fixed type
 • Thermal Trip Type: Adjustable type
 • Uimp, Impulse Withstand Voltage: 8 kV
 • Ui, Rated Insulation Voltage: 690 V (rms)
 • Un, Nominal Operational Voltage, AC: 690 V AC
 • Un, Nominal Operational Voltage, DC: 250 V DC
 • Weight: 0.8 kg
 • Width: 75 mm
 • Reverse Connection Of Supply Possible: Yes

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type MCCB AC
Number of Pole 3
Height 130 mm
Width 75 mm
Weight 0.8 kg
Rated Current 125 A @45°C
Rated Insulation Voltage 690 V (rms)
Trip Unit Technology Adjustable Thermal, Fixed Magnetic