Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Terasaki - Tb2 MCCB 65Ka 3P 63A Magnetic Only - S125GJ363MAG

  • TERASAKI
  • BW#: 00847743
  • Mfr#: S125GJ363MAG
  • UNSPSC#: 39121616
Login or Register to view price
QTY

Features
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications
  • MCCB sizes available from 16 to 1600A with various common frames and common accessories
  • Customer fit accessories available to enable quick and easy configuration
  • Basic or Advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available
  • The range complies with AS/NZS IEC 60947-2
  • Product Series: TemBreak 2 MCCB
  • Standards Compliance: IEC 60947-2 JIS C 8201-2-1 Ann.1 EN 60947-2 AS/NZS 60947-2 NEMA AB1
  • Certifications: CE ASTA


  • Specifications

  • Component Type MCCB: AC MCCB
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Adjustable thermal, adjustable magnetic
  • Im, Magnetic Trip Current, Max: 756
  • Im, Magnetic Trip Current, Min: 378
  • In, Rated Current at 45°C: 63
  • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 25
  • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 22
  • Ics, Rated Service Short-Circuit Breaking Capacity, 690V AC: 6
  • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 55
  • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 100
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC: 85
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 65
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 50
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 25
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 6
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 40
  • Depth: 68
  • Frame Size: 125 AF
  • Rated Frequency: 50 / 60 Hz
  • Height: 155
  • Number of Poles: 3
  • Poles: 3P
  • Electrical Service Life at Un, In: 30000
  • Mechanical service life: 30000
  • Magnetic Trip Type: Adjustable
  • Uimp, Impulse Withstand Voltage: 8
  • Ui, Rated Insulation Voltage: 800
  • Ue, Rated Operational Voltage, AC, max: 690
  • Ue, Rated Operational Voltage, DC, max: 250
  • Weight: 1.1
  • Width: 90
  • Reverse Connection Of Supply Possible: Yes
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type MCCB AC
    Number of Pole 3
    Colour White
    Height 155 mm
    Width 90 mm
    Weight 1.1 kg
    Rated Current 63 A @45°C
    Rated Insulation Voltage 800 V (rms)
    Trip Unit Technology Adjustable Thermal Adjustable Magnetic
    Customers Also Bought
    Alternate Products