Features
  • Rated current from 16 to 630 A
  • Breaking capacity from 25 to 50 kA at 400/415 V
  • 3 and 4 pole versions
  • 3 frame sizes
  • Thermal-magnetic and electronic protection available for the entire range
  • Extended, adjustable thermal protection from 0.7 to 1 times (TMD) or 0.5 to 1 times (electronic) the rating of the trip unit
  • Common accessories and auxiliaries with other Schneider Electric MCCB offers
  • Suitable for isolation
  • Earth-leakage protection by associated Vigi Module
  • Switch-disconnector versions also available
  • Compliance with international standards: IEC 60947-2, CCC, EAC and other local certifications
  • Green Premium product


  • Applications
  • Standard applications: industries, buildings
  • Earth-leakage protection
  • Motor protection
  • Generator protection
  • Switch-disconnectors


  • Specifications

  • [In] Rated current: 100 A (40 °C)
  • Product or component type: circuit breaker
  • Protection Type: overload protection (thermal)
  • Protection Type: short-circuit protection (magnetic)
  • Breaking Capacity: 40 kA Icu conforming to IEC 60947-2 at 220/240 V AC 50/60 Hz
  • Range: EasyPact
  • Device application: distribution
  • Network type: AC
  • Poles description: 4P
  • Trip unit technology: thermal-magnetic
  • Breaking Capacity: 20 kA Icu conforming to IEC 60947-2 at 440 V AC 50/60 Hz
  • Breaking capacity code: B
  • Earth-Leakage Protection: without
  • Neutral Position: left
  • Utilisation Category: category A
  • Protected Poles description: 3d
  • Device short name: CVS100B
  • Product name: EasyPact CVS
  • Trip unit rating: 100 A (40 °C)
  • Trip unit name: TM-D
  • Range of product: Easypact CVS100 250
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Circuit breaker
    Mounting Type Backplate
    Colour Black
    Height 136 mm
    Width 140 mm
    Weight 2.2 kg
    Length 192 mm
    Rated Current 100 A at 40 °C
    Air temperature for operation -25…70 °C
    Trip Unit Name TM-D
    Air temperature for storage -50…85 °C
    Network Frequency 50/60 Hz
    Electrical Durability 12000 cycles 415 V In conforming to IEC 60947-2
    Trip Unit Technology Thermal-magnetic
    Mechanical Durability 30000 cycles