Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

NHP DTCB6106C Din - MCB - C Curve - 1P - 6A - 6KA

  • NHP
  • BW#: 09938428
  • Mfr#: DTCB6106C
  • UNSPSC#: 39121603
Login or Register to view price
QTY

Features
  • High speed and rapid arc quenching technology ensuring the highest level of protection is provided


  • Specifications

     • Interrupting Rating:6 kA
     • Service Information: Product is not repairable
     • Product Series: DIN-T
     • Standards Compliance: IEC 60898, IEC 60947-2, UL 94 V-2, DIN 40046, IEC 60068-2, IEC 60077-16-3, AS/NZS 3111:2009
     • Certifications: CE, RCM
     • Add-On Devices (side add-on): Auxiliary Contacts, Motor Operator, Panelboard Switch, Shunt Trip, UVT
     • Component Type Power Distribution & Protection: MCB
     • Approval(s): N17481
     • Busbar System, Bottom: Fork, Pin
     • Busbar System, Top: Pin
     • Icn, Rated Short-Circuit Capacity, 1P, 230/400V AC: 6 kA
     • Icm, Rated Short-Circuit Making Capacity, 415V AC: 3 kA
     • NEMA AB1, Short-Circuit Capacity, 120/240V AC: 20 kA
     • In, Rated Current at 30°C: 6 A @30°C
     • Ics, Rated Service Short-Circuit Breaking Capacity, 240V AC: 10 kA
     • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60898): 100 % Icn
     • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 75 % Icu
     • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 100 % Icu
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 10 kA @220/240VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 3 kA @400/415VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, =60V DC: 20 kA
     • Depth: 76 mm
     • Details, Trip Characteristics: @400Hz = 1.5 x mag. trip; @DC = 1.4 x mag. trip
     • Dielectric Strength: 2.5kV V AC
     • Rated Frequency: 50/60 Hz
     • Height: 86 mm
     • Relative Humidity, Max: 95 %RH
     • IP Rating, Inside: IP40
     • IP Rating, Outside: IP20
     • Mounting: DIN-35 Rail Mount
     • Package Quantity: 12 qty
     • Poles: 1P
     • Flammability Rating (UL94): UL 94 V-2
     • Shock Rating: IEC 60068-2-27
     • Vibration Rating: IEC 60077-16-3
     • Insulation Resistance: 10000 MΩ
     • Electrical Service Life at Un, In: 10000 cycles
     • Mechanical Service Life: 20000 cycles
     • Shock Acceleration (Max.): 40 g
     • Shock Duration (Max.): 5 ms
     • Operating Temperature, Max: 55 °C max
     • Operating Temperature, Min: -25 °C min
     • Storage Temperature, Max: 55 °C max
     • Storage Temperature, Min: -55 °C min
     • Tightening Torque, Bottom, Nominal: 4.5 Nm
     • Tightening Torque, Top, Nominal: 4.5 Nm
     • Trip Curve: C
     • Utilisation Category: A
     • Vibration Acceleration (Max.): 3 m/s²
     • Impulse Withstand Test Voltage: 6 kV
     • Un, Nominal Operational Voltage, AC: 240 V AC
     • Un, Nominal Operational Voltage(s), AC :, V AC
     • Un, Nominal Operational Voltage, DC: 48 V DC
     • Ubmax, Service Voltage, AC, Max: 250 V AC
     • Ubmin, Service Voltage, AC, Min: 12 V AC
     • Ubmax, Service Voltage, DC, Max: 53 V DC
     • Weight: 0.12 kg
     • Width: 18 mm
     • Wire/Conductor Size, Flex Cable, Bottom, Max: 25 mm² Bottom
     • Wire/Conductor Size, Flex Cable, In, Min: 0.75 mm² In
     • Wire/Conductor Size, Flex Cable, Out, Min: 0.75 mm² Out
     • Wire/Conductor Size, Flex Cable, Top, Max: 25 mm² Top
     • Wire/Conductor Size, Rigid Cable, Bottom, Max: 35 mm² Bottom
     • Wire/Conductor Size, Rigid Cable, In, Min: 1 mm² In
     • Wire/Conductor Size, Rigid Cable, Out, Min: 1 mm² Out
     • Wire/Conductor Size, Rigid Cable, Top, Max: 35 mm² Top
     • Accessories: Yes
     • Isolator Application, IEC 60947-2: Yes
     • Neutral Pole Protected: Yes
     • Sealable: Yes
     • Trip-Free Mechanism: Yes
     • Centre Trip Position: No. Neutral Pole Switched: Yes
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 127V AC, 1P: 20 kA @127VAC, 1P
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC, 1P: 10 kA @240VAC, 1P
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 415V AC, 1P: 3 kA @415VAC, 1P
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 60V DC, 1P: 20 kA @60VDC, 1P
     • Ui, Rated Insulation Voltage @ Pollution Degree 2: 500 V
     • Ui, Rated Insulation Voltage @ Pollution Degree 3: 440 V
     • Depth: 85.6 mm

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type MCB
    Number of Pole 1P
    Voltage Rating 240 V AC
    Current Rating 6 A @30°C
    Depth 76 mm
    Width 18 mm
    Height 86 mm
    Tripping Curve C
    Weight 0.12 kg
    Mounting Mode DIN-35 Rail Mount
    Rated Impulse Withstand Volt 6 kV
    Rated Insulation Voltage Ui, Rated Insulation Voltage @ Pollution Degree 2 - 500 V
    Ui, Rated Insulation Voltage @ Pollution Degree 3 - 440 V
    Standards Compliance IEC 60898, IEC 60947-2, UL 94 V-2, DIN 40046, IEC 60068-2, IEC 60077-16-3, AS/NZS 3111:2009