Skip to content Skip to navigation menu
click to open Expanded view

Socomec VLB1256P VLB Kit - 125A - 6P - 25016011

  • socomec
  • BW#: 01395364
  • Mfr#: VLB1256P
  • UNSPSC#: 32101522
Login or Register to view price
QTY

Features
  • Double break per pole offers high durability and short-circuit withstand
  • Use of glass fibre reinforced polyester provides high mechanical and thermal resistance (does not include SLBM or VLBM modular series)
  • Quick and easy to install thanks to good centre to centre distance and connection accessories including copper connecting links
  • Wide range of accessories available which is flexible in adapting to various applications and reduces the cost of management and storage
  • All Socomec load break switches are compatible with the ergonomic IP65 S-Type Handles which features interlocking (in the ON position), padlocking, UV and chemical agent resistive material and the choice of standard blue or red/yellow colour


  • Specifications

  • Product Series: VLB
  • Standards Compliance: AS/NZS 60947-3 IEC 60947-3
  • Ie, Rated Operational Current, DC-21a, 220V: 125
  • Ie, Rated Operational Current, DC-22a, 220V: 125
  • Ie, Rated Operational Current, DC-23a, 220V: 63
  • Ie, Rated Operational Current, AC-21a, 400V: 125
  • Ie, Rated Operational Current, AC-22a, 400V: 125
  • Ie, Rated Operational Current, AC-23a, 400V: 125
  • Ie, Rated Operational Current, AC-23a, 415V: 125
  • Ie, Rated Operational Current, DC-21a, 440V: 40
  • Ie, Rated Operational Current, DC-22a, 440V: 32
  • Ie, Rated Operational Current, DC-23a, 440V: 32
  • Ie, Rated Operational Current, AC-21a, 500V: 125
  • Ie, Rated Operational Current, AC-22a, 500V: 100
  • Ie, Rated Operational Current, AC-23a, 500V: 80
  • Ie, Rated Operational Current, AC-21a, 690V: 125
  • Ie, Rated Operational Current, AC-22a, 690V: 80
  • Ie, Rated Operational Current, AC-23a, 690V: 80
  • Icw, short time withstand current, 1s (rms): 2.5
  • Icw, Short Time Withstand Current, 300ms (rms): 7
  • Depth: 69.9
  • Height: 189
  • KW Rating, AC-23a, 400V, 3ph: 55
  • KW Rating, AC-23a, 415V, 3ph: 55
  • KW Rating, AC-23a, 500V, 3ph: 55
  • KW Rating, AC-23a, 690V, 3ph: 55
  • Number of Poles: 6
  • Tightening Torque, Min: 4
  • Uimp, Impulse Withstand Voltage: 8
  • Ui, Rated Insulation Voltage: 800
  • Width: 187
  • Cable Cross Section (Max): 70 mm²
  • Cable Cross Section (Min): 10 mm²
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Pole 6
    Height 190 mm
    Width 350 mm
    Length 210 mm
    Weight 4000 g