Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

ABB - Contactor - 110V 50Hz / 110-120V 60Hz - 1SFL531001R8411 - A260-30-11-84

  • ABB
  • BW#: 01130759
  • Mfr#: A260301184
  • UNSPSC#: 32101522
Login or Register to view price
QTY

Applications
  • A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V


  • Specifications

  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 1
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 400 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 400 A
  • (690 V) 55 °C 350 A
  • (690 V) 70 °C 290 A
  • Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 260 A
  • (380 / 400 V) 55 °C 260 A
  • (415 V) 55 °C 260 A
  • (440 V) 55 °C 240 A
  • (500 V) 55 °C 240 A
  • (690 V) 55 °C 220 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 80 KWT
  • (380 / 400 V) 140 KWT
  • (415 V) 140 KWT
  • (440 V) 140 KWT
  • (500 V) 180 KWT
  • (690 V) 200 KWT
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 500 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A
  • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A
  • Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
  • AC-2 / AC-4 150 cycles per hour
  • AC-3 300 cycles per hour
  • Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 400 A
  • (220 V) 3 Poles in Series, 40 °C 400 A
  • Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 400 A
  • (220 V) 3 Poles in Series, 40 °C 400 A
  • Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 400 A
  • (220 V) 3 Poles in Series, 40 °C 400 A
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V
  • acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
  • Mechanical Durability: 5 million
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc): 50 Hz 110 V
  • 60 Hz 110 ... 120 V
  • Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
  • Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
  • Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
  • Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
  • Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 13 ms
  • Between Coil De-energization and NO Contact Opening 10 ... 16 ms
  • Between Coil Energization and NC Contact Opening 12 ... 30 ms
  • Between Coil Energization and NO Contact Closing 17 ... 35 ms
  • Connecting Capacity Main Circuit: Bar 32 mm
  • Rigid Al-Cable 2 x 95 ... 120 m²
  • Rigid Cu-Cable 16 ... 240 m²
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 ... 2.5
  • Flexible with Insulated Ferrule 1x 0.75 ... 2.5
  • Flexible 2x0.75 ... 2.5 m²
  • Solid 1 x 1 ... 4 m²
  • Stranded 2 x 1 .... 4 m²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Connecting Terminals (delivered in open position) Main Poles: Flat type c/w screws and bolts
  • Terminal Type: Main Circuit: Bars
  • Dimensions
  • Product Net Width: 140 mm
  • Product Net Depth / Length: 180.5 mm
  • Product Net Height: 227 mm
  • Product Net Weight: 5.4 kg