Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric TeSys GV4 GV4PE25N Motor Circuit breaker - Thermal Magnetic EverLink Terminals - 3P - 25A Icu - 50kA

  • Schneider Electric
  • BW#: 00472485
  • Mfr#: GV4PE25N
  • UNSPSC#: 39122000
Login or Register to view price
QTY

Features
 • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
 • GV4 Type P : Magnetic short circuit and overload protection
 • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
 • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
 • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
 • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
 • Ergonomic rotary handle for easy switching and controlling with clear trip indication
 • Other options include: Toggle, side, extended

Applications
 • Oil & Gas
 • Wastewater treatment facilities
 • Mining
 • Energy

Specifications

  • Motor tripping class: 10

  • Trip unit technology: Electronic

  • Utilisation category: Category A

  • Protection type: Phase unbalance

  • [Ics] Rated service breaking capacity: 100 kA : at 220 240 V AC 50/60 Hz according to IEC 60947-2

  • [Ics] Rated service breaking capacity: 25 kA : at 500 V AC 50/60 Hz according to IEC 60947-2

  • Device short name: GV4P

  • Breaking capacity: 65 kA at 240 V AC 50/60 Hz according to UL 60947

  • Breaking capacity: [Icu] : 8 kA at 660 690 V AC 50/60 Hz according to IEC 60947-2

  • Breaking capacity: [Icu] : 25 kA at 500 V AC 50/60 Hz according to IEC 60947-2

  • Protection type: Short time short-circuit protection

  • Protection type: Overload

  • Device application: Motor

  • Protection type: Phase loss

  • [Ics] Rated service breaking capacity: 50 kA : at 380 415 V AC 50/60 Hz according to IEC 60947-2

  • [Ics] Rated service breaking capacity: 15 kA : at 525 V AC 50/60 Hz according to IEC 60947-2

  • [Ics] Rated service breaking capacity: 2 kA : at 660 690 V AC 50/60 Hz according to IEC 60947-2

  • Breaking capacity: [Icu] : 100 kA at 220 240 V AC 50/60 Hz according to IEC 60947-2

  • [In] Rated current: 25 A

  • Motor tripping class: 20

  • Protection type: Ground fault protection

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type Circuit Breaker
Height 155 mm
Width 81 mm
Weight 1.45 kg
Length 155 mm
Pollution Degree 3
Air temperature for storage -50-85 °C
Product Certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Rated Supply Voltage 380...480 V
380...480 V - 15...10 %