Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric TeSys GV4 GV4PE07N Motor Circuit breaker - Thermal Magnetic EverLink Terminals - 3P - 7A Icu - 50kA

  • Schneider Electric
  • BW#: 00472825
  • Mfr#: GV4PE07N
  • UNSPSC#: 39122000
Login or Register to view price
QTY

Features
  • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
  • GV4 Type P : Magnetic short circuit and overload protection
  • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
  • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
  • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
  • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
  • Ergonomic rotary handle for easy switching and controlling with clear trip indication
  • Other options include: Toggle, side, extended


  • Applications
  • Oil & Gas
  • Wastewater treatment facilities
  • Mining
  • Energy


  • Specifications

    • Motor tripping class: 20

    • Utilisation category: Category A

    • Protection type: Phase unbalance

    • Product name: TeSys GV4

    • Breaking capacity: 65 kA at 208Y/120 V AC 50/60 Hz according to UL 60947

    • Breaking capacity: [Icu] : 50 kA at 380 415 V AC 50/60 Hz according to IEC 60947-2

    • Breaking capacity: [Icu] : 50 kA at 440 V AC 50/60 Hz according to IEC 60947-2

    • [In] Rated current: 7 A

    • Poles description: 3P

    • Product or component type: Circuit breaker

    • Protection type: Ground fault protection

    • Protection type: Short time short-circuit protection

    • Protection type: Short-circuit

    • Trip unit technology: Thermal-magnetic

    • Device application: Motor

    • [Ics] Rated service breaking capacity: 50 kA : at 380 415 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated service breaking capacity: 25 kA : at 500 V AC 50/60 Hz according to IEC 60947-2

    • Trip unit rating: 2.9 7 A

    • Breaking capacity: 65 kA at 240 V AC 50/60 Hz according to UL 60947

    • Breaking capacity: 18 kA at 600Y/347 V AC 50/60 Hz according to UL 60947

    • Control type: Toggle

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Circuit Breaker
    Height 155 mm
    Width 81 mm
    Weight 1.45 kg
    Length 155 mm
    Pollution Degree 3
    Air temperature for storage -50-85 °C
    Product Certifications IEC
    UL
    CSA
    CCC
    EAC
    ATEX
    EU-RO MR