Schneider Electric TeSys GV4 GV4P80B Motor Circuit breaker - Thermal Magnetic EverLink Terminals - 3P - 80A Icu - 25kA

  • Schneider Electric
  • BW#: 00472944
  • Mfr#: GV4P80B
  • UNSPSC#: 39122000

Features
  • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
  • GV4 Type P : Magnetic short circuit and overload protection
  • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
  • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
  • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
  • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
  • Ergonomic rotary handle for easy switching and controlling with clear trip indication
  • Other options include: Toggle, side, extended


  • Applications
  • Oil & Gas
  • Wastewater treatment facilities
  • Mining
  • Energy


  • Specifications

    • [In] Rated current: 80 A

    • Poles description: 3P

    • Protection type: Short time short-circuit protection

    • Protection type: Short-circuit

    • Trip unit technology: Thermal-magnetic

    • Device application: Motor

    • Breaking capacity: [Icu] : 20 kA at 440 V AC 50/60 Hz according to IEC 60947-2

    • Protection type: Ground fault protection

    • Trip unit technology: Electronic

    • Range: TeSys

    • [Ics] Rated service breaking capacity: 50 kA : at 220 240 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated service breaking capacity: 25 kA : at 380 415 V AC 50/60 Hz according to IEC 60947-2

    • Breaking capacity: 35 kA at 208Y/120 V AC 50/60 Hz according to UL 60947

    • Breaking capacity: [Icu] : 25 kA at 380 415 V AC 50/60 Hz according to IEC 60947-2

    • Trip unit rating: 40 80 A

    • Motor tripping class: 10

    • Protection type: Phase loss

    • [Ics] Rated service breaking capacity: 20 kA : at 440 V AC 50/60 Hz according to IEC 60947-2

    • Device short name: GV4P

    • Breaking capacity: 18 kA at 480Y/277 V AC 50/60 Hz according to UL 60947

    • Breaking capacity: [Icu] : 50 kA at 220 240 V AC 50/60 Hz according to IEC 60947-2

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Circuit Breaker
    Height 155 mm
    Width 81 mm
    Weight 1.6 kg
    Length 155 mm
    Pollution Degree 3
    Air temperature for storage -50-85 °C
    Product Certifications IEC
    UL
    CSA
    CCC
    EAC
    ATEX
    EU-RO MR