Skip to content Skip to navigation menu
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Schneider - TeSys GV4 - Thermal Magnetic Circuit Breaker - 115A 3P - with compression lug - GV4PE115N6

  • Schneider Electric
  • BW#: 00472536
  • Mfr#: GV4PE115N6
  • UNSPSC#: 39122000

Features
 • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
 • GV4 Type P : Magnetic short circuit and overload protection
 • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
 • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
 • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
 • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
 • Ergonomic rotary handle for easy switching and controlling with clear trip indication
 • Other options include: Toggle, side, extended

Applications
 • Oil & Gas
 • Wastewater treatment facilities
 • Mining
 • Energy

Specifications

  • Poles description: 3P

  • Protection type: Short time short-circuit protection

  • Protection type: Short-circuit

  • Trip unit technology: Thermal-magnetic

  • Device application: Motor

  • [Ics] Rated service breaking capacity: 50 kA : at 380 415 V AC 50/60 Hz according to IEC 60947-2

  • [Ics] Rated service breaking capacity: 25 kA : at 500 V AC 50/60 Hz according to IEC 60947-2

  • Breaking capacity: 18 kA at 600Y/347 V AC 50/60 Hz according to UL 60947

  • Control type: Toggle

  • Protection type: Ground fault protection

  • Trip unit technology: Electronic

  • Range: TeSys

  • [Ics] Rated service breaking capacity: 50 kA : at 440 V AC 50/60 Hz according to IEC 60947-2

  • [Ics] Rated service breaking capacity: 2 kA : at 660 690 V AC 50/60 Hz according to IEC 60947-2

  • Breaking capacity: [Icu] : 100 kA at 220 240 V AC 50/60 Hz according to IEC 60947-2

  • Breaking capacity: [Icu] : 8 kA at 660 690 V AC 50/60 Hz according to IEC 60947-2

  • Motor tripping class: 20

  • Product or component type: Circuit breaker

  • Utilisation category: Category A

  • Protection type: Phase unbalance

  • [Ics] Rated service breaking capacity: 100 kA : at 220 240 V AC 50/60 Hz according to IEC 60947-2

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type Circuit Breaker
Height 155 mm
Width 81 mm
Weight 1.45 kg
Length 220 mm
Pollution Degree 3
Air temperature for storage -50-85 °C
Product Certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR