Skip to content Skip to navigation menu
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Schneider - TeSys GV4 - Magnetic Circuit Breaker - 115A 3P - with EverLink - GV4LE115B

  • Schneider Electric
  • BW#: 00470258
  • Mfr#: GV4LE115B
  • UNSPSC#: 39122000

Features
  • GV4 Type L: Magnetic short circuit protection to be used with an overload relay or a drive
  • GV4 Type P : Magnetic short circuit and overload protection
  • GV4 PEM: Magnetic short circuit and overload protection with advanced settings and pre-alarming
  • Covers motor protection from 0.25 to 55 kW at 415 V AC (from 0.8 to 115 A) all in one frame
  • Available in three different breaking capacities: 25, 50 and 100 kA at 415 V AC IEC (15, 35, 65 kA at 480 V UL)
  • Patented EverLink creep-compensating technology: Spring-based system ensures a long-lasting connection, improve overheating leading to trip, reduce risk during short circuit
  • Ergonomic rotary handle for easy switching and controlling with clear trip indication
  • Other options include: Toggle, side, extended


  • Applications
  • Oil & Gas
  • Wastewater treatment facilities
  • Mining
  • Energy


  • Specifications

    • [Ics] Rated service breaking capacity: 20 kA : at 440 V AC 50/60 Hz according to IEC 60947-2

    • Breaking capacity: [Icu] : 50 kA at 220 240 V AC 50/60 Hz according to IEC 60947-2

    • Breaking capacity: [Icu] : 25 kA at 380 415 V AC 50/60 Hz according to IEC 60947-2

    • Breaking capacity: [Icu] : 10 kA at 500 V AC 50/60 Hz according to IEC 60947-2

    • Control type: Toggle

    • Range: TeSys

    • [Ics] Rated service breaking capacity: 50 kA : at 220 240 V AC 50/60 Hz according to IEC 60947-2

    • [Ics] Rated service breaking capacity: 25 kA : at 380 415 V AC 50/60 Hz according to IEC 60947-2

    • Device short name: GV4L

    • [In] Rated current: 115 A

    • Product or component type: Circuit breaker

    • Protection type: Short-circuit

    • Trip unit technology: Magnetic

    • Device application: Motor

    • Trip unit rating: 690 1610 A

    • Breaking capacity: [Icu] : 20 kA at 440 V AC 50/60 Hz according to IEC 60947-2

    • Poles description: 3P

    • Utilisation category: Category A

    • [Ics] Rated service breaking capacity: 10 kA : at 500 V AC 50/60 Hz according to IEC 60947-2

    • Product name: TeSys GV4

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Circuit Breaker
    Height 110 mm
    Width 165 mm
    Weight 1700 g
    Length 220 mm
    Pollution Degree 3
    Product Certifications IEC
    CCC
    EAC
    EU-RO MR