Skip to content Skip to navigation menu
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Schneider - Switch-Disconnector Compact - INS160 - 4 poles - 160 A - 28913

  • Schneider Electric
  • BW#: 00691785
  • Mfr#: 28913
  • UNSPSC#: 39122000

Features
  • Nominal current: 40 to 2500 A
  • Rated operational current for AC22A, AC23A and DC22A, DC23A
  • High short-circuit making capacity for the switch disconnector alone and with upstream protection circuit breaker
  • High short-time withstanding current
  • 3 and 4 pole versions available
  • IP66 and IP55 local isolation enclosure
  • Suitable for isolation with positive contact indication
  • Locking by up to three padlocks or lead-sealed in the off position


  • Applications
  • Power distribution incomers for large buildings (commercial buildings, offices, etc. )
  • Sub-distribution incomers for mid-size buildings (hotel, hospitals, etc.)
  • Final distribution outgoers and local isolation and for industrial applications
  • Source-changeover systems (TransferPact): service sector (hospital operating rooms, computer rooms, etc.), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)
  • Specific applications: photovoltaic and emergency-off versions available
  • Applications in the harshest environments (tunnels); IP66 enclosed


  • Specifications

  • [Icm] Rated short circuit making capacity : 154 kA 690 V AC 50/60 Hz with upstream protection circuit breaker
  • [Ith] Conventional free air thermal current : 125 A (60 °C)
  • Product or component type : Switch disconnector
  • Visible break : No
  • [Ie] Rated operational current : 125 A AC 50/60 Hz for 660/690 V in category AC-22A
  • Pollution degree : 3
  • [Uimp] Rated impulse withstand voltage : 8 kV
  • [Icm] Rated short circuit making capacity : 20 kA 690 V AC 50/60 Hz switch disconnector alone
  • Suitability for isolation : Yes
  • Range of product : INS40 160
  • [Ie] Rated operational current : 125 A AC 50/60 Hz for 220/240 V in category AC-22A
  • [Ie] Rated operational current : 125 A AC 50/60 Hz for 380/415 V in category AC-22A
  • [Ie] Rated operational current : 125 A AC 50/60 Hz for 440/480 V in category AC-23A
  • [Ie] Rated operational current : 125 A AC 50/60 Hz for 500 V in category AC-23A
  • [Ie] Rated operational current : 80 A AC 50/60 Hz for 660/690 V in category AC-23A
  • [Ie] Rated operational current : 125 A DC for 125 V in category DC-22A (2 poles in series)
  • [Ue] Rated operational voltage : 250 V DC
  • [Ue] Rated operational voltage : 690 V AC 50/60 Hz
  • Network frequency : 50/60 Hz
  • Network type : DC
  • Contact position indicator : Yes
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Switch Disconnector
    Height 100 mm
    Width 135 mm
    Weight 0.9 kg
    Length 154 mm
    Air temperature for operation -25-70 °C
    Pollution Degree 3
    Network Frequency 50/60 Hz
    Air temperature for storage -50-85 °C
    Product Certifications CCC
    KEMA-KEUR
    IP degree of protection IP40 conforming to IEC 60529