Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Sprecher + Schuh Sprecher + Schuh (View All Products)

Sprecher + Schuh - Switch Complete 2P Changeover 12A Panel Mount - CALE2122502

  • Sprecher + Schuh
  • BW#: 00920265
  • Mfr#: CALE2122502
  • UNSPSC#: 39121529
Login or Register to view price
QTY

Features
  • L2 rotary cam switches are available for all control and load applications from 12 up to 25 amps in base or panel mount with renowned modular, convenience and safety features
  • Stackable wafers and multiple cam cuttings provide maximum switching options with as few as two and as many as 16 contacts


  • Applications
  • A wide range of stocked configurations including control switches, motor switches, multi-position load switches, motor load disconnect switches, isolating switches and more for whatever you may need


  • Specifications

  • Ie, Rated Current, DC-21a, Inductive Load @110V per contact: 0.4
  • Ie, Rated Current, DC-21a, Resistive Load @110V per contact: 2
  • Ie, Rated Operational Current, AC-15, 220-240V: 5
  • Ie, Rated Operational Current, AC-22a, 220-500V: 12
  • Ie, Rated Current, DC-21a, Resistive Load @220V per contact: 0.5
  • Ie, Rated Current, DC-21a, Inductive Load @24V per contact: 8
  • Ie, Rated Current, DC-21a, Resistive Load @24V per contact: 12
  • Ie, Rated Current, DC-21a, Inductive Load @30V per contact: 4.5
  • Ie, Rated Operational Current, AC-15, 380-415V: 3
  • Ie, Rated Current, DC-21a, Resistive Load @440V per contact: 0.4
  • Ie, Rated Current, DC-21a, Inductive Load @48V per contact: 1.5
  • Ie, Rated Current, DC-21a, Resistive Load @48V per contact: 10
  • Ie, Rated Operational Current, AC-22a, 600V: 12
  • Ie, Rated Current, DC-21a, Inductive Load @60V per contact: 1
  • Ie, Rated Current, DC-21a, Resistive Load @60V per contact: 8
  • Ie, Rated Operational Current, AC-1, 690V: 12
  • Ie, Rated Operational Current, AC-21a, 690V: 12
  • Inc, Rated Conditional Short Circuit Current: 5
  • Ithe, Thermal Current, Enclosed: 12
  • Ith, Thermal Current, Open: 16
  • Depth: 82
  • Rated Frequency: 50 / 60 Hz
  • Fuse Characteristic Type(s): gL/gG
  • Series Fuse Current Rating, Max: 35
  • Height: 48
  • IP Rating: IP20 IP65
  • kW Rating, AC-23a, 110V, 1ph: 0.75
  • kW Rating, AC-23a, 220-240V, 1ph: 1.3
  • kW Rating, AC-23a, 220-240V, 3ph: 2.2
  • kW Rating, AC-23a, 380-440V, 1ph: 2.2
  • kW Rating, AC-23a, 380-440V, 3ph: 4
  • kW Rating, AC-23a, 500V, 3ph: 5.5
  • kW Rating, AC-23a, 660V, 3ph: 5.5
  • Manufacturer Catalogue & Product Selection: CALE2122502_Manufacturer Catalogue
  • Mounting: Panel Mount
  • Max Contacts @110V DC, Inductive Load, DC21a: 2
  • Max Contacts @110V DC, Resistive Load, DC21a: 2
  • Max Contacts @220V DC, Resistive Load, DC21a: 2
  • Max Contacts @24V DC, Inductive Load, DC21a: 2
  • Max Contacts @24V DC, Resistive Load, DC21a: 2
  • Max Contacts @30V DC, Inductive Load, DC21a: 2
  • Max Contacts @440V DC, Resistive Load, DC21a: 1
  • Max Contacts @48V DC, Inductive Load, DC21a: 2
  • Max Contacts @48V DC, Resistive Load, DC21a: 2
  • Max Contacts @60V DC, Inductive Load, DC21a: 2
  • Max Contacts @60V DC, Resistive Load, DC21a: 2
  • Number of Poles: 2
  • Power factor, breaking @ 220V AC: ≥0.65
  • Power factor, breaking @ 380V AC: ≥0.65
  • Power factor, breaking @ 660V AC: ≥0.65
  • Pe, Rated Operational Power, AC 3, 110V AC, 1Ø: 0.75
  • Pe, Rated Operational Power, AC 3, 220-240V AC, 1Ø: 1.3
  • Pe, Rated Operational Power, AC 3, 220-240V AC, 3Ø: 2.2
  • Operational Power, AC 4, 220-240V AC: 0.75
  • Operational Power, AC 2, 240V AC: 3
  • Operational Power, AC 4, 380-415V AC: 1.5
  • Pe, Rated Operational Power, AC 3, 380-440V AC, 1Ø: 2.2
  • Pe, Rated Operational Power, AC 3, 380-440V AC, 3Ø: 4
  • Operational Power, AC 2, 380V AC: 5.5
  • Operational Power, AC 2, 415V AC: 5.5
  • Operational Power, AC 4, 440-550V AC: 1.5
  • Operational Power, AC 2, 440V AC: 5.5
  • Operational Power, AC 2, 500V AC: 7.5
  • Pe, Rated Operational Power, AC 3, 500V AC, 3Ø: 5.5
  • Operational Power, AC 2, 660V AC: 7.5
  • Pe, Rated Operational Power, AC 3, 660V AC, 3Ø: 5.5
  • Electrical Operation Rate, Max: 120
  • Mechanical Operation Rate, Max: 1200
  • Mechanical service life: 1000000
  • Switching Angle: 60°
  • Operating Temperature, Max: 60
  • Operating Temperature, Min: -25
  • Storage Temperature, Max: 80
  • Storage Temperature, Min: -40
  • Tightening Torque, Max: 1
  • Uimp, Impulse Withstand Voltage: 6
  • Ui, Rated Insulation Voltage: 690
  • Un, Nominal Operational Voltage, AC: 690
  • Width: 48
  • Wire / Conductor Size, Flex Cable, Max: 12 AWG ( 3.31 mm² )
  • Wire / Conductor Size, Flex Cable, Min: 18 AWG ( 0.823 mm² )
  • Wire / Conductor Size (Max): 12 AWG ( 3.31 mm² )
  • Wire / Conductor Size, Rigid Cable, Max: 12 AWG ( 3.31 mm² )
  • Wire / Conductor Size, Rigid Cable, Min: 18 AWG ( 0.823 mm² )
  • Switching Function: Changeover without Off
  • Product Series: L2
  • Standards Compliance: EN 60947-3 IEC 60947-3 IEC 60529 IEC 60947
  • Certifications: CE CSA UL
  • Altitude, Operating, Max: 2000
  • Current, Breaking Capacity, 220V AC: 72
  • Current, Breaking Capacity, 380V AC: 72
  • Current, Breaking Capacity, 660V AC: 53
  • Im, Rated Make/Break Capacity, DC-21a, Resistive@115.5V DC per contact: 3
  • Im, Rated Make/Break Capacity, DC-21a, Inductive@121V DC per contact: 0.44
  • Im, Rated Make/Break Capacity, DC-21a, Resistive@231V DC per contact: 0.75
  • Im, Rated Make/Break Capacity, DC-21a, Resistive@25.2V DC per contact: 18
  • Im, Rated Make/Break Capacity, DC-21a, Inductive@26.4V DC per contact: 8.8
  • Im, Rated Make/Break Capacity, DC-21a, Inductive@33V DC per contact: 4.95
  • Im, Rated Make/Break Capacity, DC-21a, Resistive@462V DC per contact: 0.52
  • Im, Rated Make/Break Capacity, DC-21a, Resistive@50.4V DC per contact: 15
  • Im, Rated Make/Break Capacity, DC-21a, Inductive@52.8V DC per contact: 1.65
  • Im, Rated Make/Break Capacity, DC-21a, Resistive@63V DC per contact: 12
  • Im, Rated Make/Break Capacity, DC-21a, Inductive@66V DC per contact: 1.1
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Number of Pole 2
    Mounting Type Panel Mount
    Width 48 mm
    Depth 82 mm
    Height 48 mm
    Certification/Standard CE, CSA, UL
    IP degree of protection IP20, IP65