Features
  • The special armature structure design allows all devices and all operating coils, either AC or DC, to have the same physical size and panel footprint for convenience
  • Devices are available with low consumption DC operating coils for direct connection to PLC circuits
  • Three contactor ratings for the USA market: K06 rated for 3 HP motors at 480 VAC or 600 VAC, K09 rated for 5 HP motors at 480 VAC or 600 VAC, K12 rated for 7.5 HP motors at 480 VAC or 10 HP at 600 VAC
  • IP20 finger-safe terminals
  • Mountable on 35mm DIN rail or panel mount with screws
  • Available in 3-pole contactor versions with built-in auxiliary contact for holding circuit or 4-pole contactor versions
  • Current rating from 6-12A
  • Simple to select the right product
  • Easily-installed accessories: 2-pole or 4-pole instantaneous auxiliary contact blocks with screw clamp, slip-on, or spring terminals, transient voltage surge suppressors, Electronic 1 to 30 second on-delay timers
  • Four wiring methods to reduce installation time: Captive screw terminals for use with either Phillips or slotted head screwdrivers, slip-on terminals for quick installation of single 1/4" or double 1/8" tabs, terminal pins for soldering the contactor directly to a printed circuit board, spring terminals for extreme-vibration applications
  • Control circuit flexibility


  • Applications
  • TeSys K contactors and overload relays are ideal for general duty applications where small size and reliability are key concerns


  • Specifications

  • Utilisation category:AC-3,AC-1,AC-4
  • Poles description:3P
  • Power pole contact composition:3 NO
  • [Ie] rated operational current:20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
  • 9 A at <= 440 V AC AC-3 for power circuit
  • 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
  • control circuit type:AC at 50/60 Hz
  • [Uc] control circuit voltage:24 V AC 50/60 Hz
  • Motor power kW
  • 2.2 kW at 220...230 V AC 50/60 Hz AC-3
  • 4 kW at 380...415 V AC 50/60 Hz AC-3
  • 4 kW at 440 V AC 50/60 Hz AC-3
  • 4 kW at 480 V AC 50/60 Hz AC-3
  • 4 kW at 500...600 V AC 50/60 Hz AC-3
  • 4 kW at 660...690 V AC 50/60 Hz AC-3
  • 2.2 kW at 400 V AC 50/60 Hz AC-4
  • Auxiliary contact composition:1 NO
  • overvoltage category:III
  • [Ith] conventional free air thermal current
  • 20 A (at 50 °C) for power circuit
  • 10 A (at 50 °C) for signalling circuit
  • Irms rated making capacity
  • 110 A AC for power circuit conforming to NF C 63-110
  • 110 A AC for power circuit conforming to IEC 60947
  • 110 A AC for signalling circuit conforming to IEC 60947
  • Rated breaking capacity
  • 110 A at 415 V conforming to IEC 60947
  • 110 A at 440 V conforming to IEC 60947
  • 80 A at 500 V conforming to IEC 60947
  • 110 A at 220...230 V conforming to IEC 60947
  • 110 A at 380...400 V conforming to IEC 60947
  • 70 A at 660...690 V conforming to IEC 60947
  • Associated fuse rating
  • 25 A gG at <= 440 V for power circuit
  • 25 A aM for power circuit
  • 10 A gG for signalling circuit conforming to IEC 60947
  • 10 A gG for signalling circuit conforming to VDE 0660
  • Average impedance:3 mOhm - Ith 20 A 50 Hz for power circuit
  • Insulation resistance:> 10 MOhm for signalling circuit
  • inrush power in VA:30 VA (at 20 °C)
  • Hold-in power consumption in VA:4.5 VA (at 20 °C)
  • heat dissipation:1.3 W
  • control circuit voltage limits
  • Operational: 0.8...1.15 Uc (at <50 °C)
  • Drop-out: 0.2...0.75 Uc (at <50 °C)
  • Maximum operating rate:3600 cyc/h
  • Auxiliary contacts type:Type instantaneous 1 NO
  • signalling circuit frequency:<= 400 Hz
  • Minimum switching current:5 mA for signalling circuit
  • Minimum switching voltage:17 V for signalling circuit
  • Operating time
  • 10...20 ms coil de-energisation and NO opening
  • 10...20 ms coil energisation and NO closing
  • Safety reliability level
  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Non overlap distance:0.5 mm
  • Mechanical robustness
  • Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
  • Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
  • Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
  • Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
  • Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
  • Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
  • Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
  • Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
  • Environment
  • product certifications:CSA,UL
  • protective treatment:TC conforming to IEC 60068,TC conforming to DIN 50016
  • Operating altitude:2000 m without derating
  • Flame retardance
  • V1 conforming to UL 94
  • Requirement 2 conforming to NF F 16-101
  • Requirement 2 conforming to NF F 16-102
  • Offer Sustainability
  • Sustainable offer status
  • Green Premium product
  • REACh Regulation:REACh Declaration
  • REACh free of SVHC:Yes
  • EU RoHS Directive:Compliant,EU RoHS Declaration
  • Mercury free:Yes
  • RoHS exemption information:Yes
  • China RoHS Regulation:Product out of China RoHS scope. Substance declaration for your information
  • Environmental Disclosure
  • Product Environmental Profile
  • Circularity Profile
  • End of Life Information
  • WEEE:The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • Warranty:18 months
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type contactor
    Number of Pole 3P
    Mounting Type DIN Rail
    Width 62 mm
    Depth 57 mm
    Height 48 mm
    Certification/Standard CSA
    UL
    UKCA
    Weight 179 g
    Length 66 mm
    Pole Contact Composition 3 NO