Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Eaton - Surge filter - 100A - 3PH - 80kA - Enclosed - PPF1003CEI

  • Eaton
  • BW#: 01130827
  • Mfr#: PPF1003CEI
  • UNSPSC#: 39101600
Login or Register to view price
QTY

Features
  • The Eaton PPFi is designed to provide point-of-entry (Category C) & sub-circuit protection (Category B) against power surges caused by external sources such as lightning strikes & substation switching as well as providing a measure of protection from surge events generated on the secondary side of the filter
  • The Eaton PPFi is a 3-stage protection system utilizing primary & secondary MOV protection in conjunction with a low-Q LC filter
  • The unit provides filtering of the line harmonics, noise & RF transmitters with a cut-off frequency of <10Hz & a minimum attenuation of 70dB above 1MHz
  • Special care has been taken in the design of the filter to minimize ringing caused by light loads, surge diverter operation & inductive load back-EMF


  • Applications
  • An ideal device for all category locations


  • Specifications

  • Dimensions (H x W x D, mm): 800 x 600 x 200
  • Weight (kg): 50
  • Warranty: 5 years

  • Electrical:
  • Input voltage: 380 - 440VAC 3 Phase
  • Max Continuous Voltage (Mcov): 300VAC L-N
  • Temporary overvoltage - TOV: 320VAC, 15 mins
  • Test classification: Class II
  • Primary protection L-N: CEi: 1,200J/ph, 3,600J total. DEi: 1,800J/ph, 5400J total. EEi: 3,600J/ph, 10,8000J total
  • Secondary protection L-N: CEi: 600J/ph, 1,600J total. DEi: 600J/ph, 1,800J total. EEi: 600J/ph, 1,800J total
  • Common mode protection N-E:CEi: 2,130J. DEi: 710J. EEi: 710J
  • Aggregate rating: CEi: 7,530J. DEi: 7,910J.. EEi: 13,310J
  • Current rating continuous (standard models): 100A
  • Recommended maximum over current protection: 100A
  • Residual current: <1 mA
  • Short circuit withstand (1 sec): 29kA
  • Protection modes: Line-Neutral, Neutral-Earth
  • In 8/20us (Line-Neutral) Nominal Surge Life: CEi: 30kA x 20 hits/ph; DEi: 45kA x 20 hits/ph; EEI: 90kA x 20 hits/ph
  • In 8/20us (Neutral-Earth) Nominal Surge Life: 45kA x 20 hits
  • Ismax 8/20us (Line-Neutral) Max surge level: CEi: 80kA; DEi: 120kA; EEI: 240kA
  • Ismax 8/20us (Neutral-Earth) Max surge level: CEi: 120kA; DEi: 40kA; EEI: 40kA
  • Filter attenuation: 70dB nominal above 1MHz
  • Initial clamp voltage (Line-Neutral): 560V (350Vac RMS)
  • Initial clamp voltage (Line-Earth): 1240V (700Vac RMS)
  • Initial clamp voltage (Neutral-Earth): 680V (420Vac RMS)
  • Residual voltage (Vpl) Line-Neutral: <900Vac (3kA, 8/20uS) IEC61643.1
  • Residual voltage (Vpl) Line-Earth: <1100Vac (3kA, 8/20uS) IEC61643.1
  • Residual voltage (Vpl) Neutral-Earth: <1000Vac (3kA, 8/20uS) IEC61643.1
  • Internal protection (fusing): All surge diverter connections are fused via HRC fuses to IEC269-2-1
  • Terminations: Bolted lug. 8mm bolts for phase & neutral connections
  • 8mm PE (earth) stud provided on geartray

  • Communications:
  • Alarms/indicators: Mimic panel display via LED (2 colour), OK - Green; Protection Fault - Red. Dry contact alarm relay output 250Vac/32Vdc, 10A, 4kV isolation, Alarm under-voltage cutoff 180Vac

  • Environmental & Standards:
  • Enclosure rating: IP24
  • Design standards: IEC61643-1, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B,C,D AS1768-2007 Cat B,C,D,E AS3000, AS3100, CE mark
  • Environment: -10 to 65C, 10 to 90%RH (non-condensing)
  • Minimum sell quantity:

    Order Quantity Multiple: