Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view

Eldon - NHP - Cable Gland - Rubber - Grey - Ip67 Suits Diameter - 5-9 mm - CED16

  • ELDOn
  • BW#: 00354913
  • Mfr#: CED16
  • UNSPSC#: 31181702
Login or Register to view price
QTY

Features
  • Easily installed and economically priced

  • High ingress protection, IP 67

  • Temperature resistance: -40°C to +110°C

  • Suitable for holes in materials of 05 to 4mm thickness

  • Chemical and oil resistant

  • Excellent insulation and mechanical properties

  • Made from one piece EPDM and halogen free


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

  • Service Information: Product is not repairable
  • Product Series: TemBreak 2 MCCB
  • Standards Compliance: IEC 60947-2, EN 60947-2, JIS C 8201-2-1 Ann.1, AS/NZS 60947-2, NEMA AB1
  • Certifications: CE, ASTA
  • Shipping Approvals: Contact NHP
  • Component Type MCCB: MCCB AC
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Adjustable Thermal Adjustable Magnetic
  • Im, Magnetic Trip Current, Max: 240 A
  • Im, Magnetic Trip Current, Min: 120 A
  • In, Rated Current at 45°C: 20 A @45°C
  • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 25 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 22 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
  • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 100 % Icu
  • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 76 % Icu
  • Ir, Thermal Trip Current, Max: 20 A
  • Ir, Thermal Trip Current, Min: 12.5 A
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC: 50 kA @240VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 36 kA @400/415VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 25 kA @440VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 22 kA @525VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 25 kA @250VDC
  • Depth: 68 mm
  • Frame Size: 125 AF size
  • Rated Frequency: 50/60 Hz
  • Height: 155 mm
  • Number of Poles: 3
  • Poles: 3P
  • Electrical Service Life at Un, In: 30000 cycles
  • Mechanical Service Life: 30000 cycles
  • Magnetic Trip Type: Adjustable type
  • Thermal Trip Type: Adjustable type
  • Uimp, Impulse Withstand Voltage: 8 kV
  • Ui, Rated Insulation Voltage: 800 V (rms)
  • Ue, Rated Operational Voltage, AC, max: 690 V AC
  • Ue, Rated Operational Voltage, DC, max: 250 V DC
  • Weight: 1.1 kg
  • Width: 90 mm
  • Reverse Connection Of Supply Possible: Yes
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Colour Grey
    Customers Also Bought
    Alternate Products