Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric ABLS1A24050 - Regulated Power Supply - Modicon - 100-240V AC - 24V - 5 A - 120W - Single Phase - Optimized

  • Schneider Electric
  • BW#: 02830198
  • Mfr#: ABLS1A24050
  • UNSPSC#: 39121004
Login or Register to view price
QTY

Features
 • Compact dimensions
 • Integrated overload, short-circuit, overvoltage, and undervoltage protection
 • Wide input voltage range
 • High degree of output voltage stability

Applications
 • Power supplies for industrial use, rail mounting

Specifications

 • Output Coupling : Parallel, Serial
 • Standards : EN 62368-1
 • EN/IEC61204-3
 • EN 61000-6-1
 • EN 61000-6-2
 • EN 61000-6-3
 • EN 61000-6-4
 • EN 61000-3-2
 • EN 61000-3-3
 • Ul 62368-1
 • CSA C22.2 No 62368-1
 • Ul 508
 • CSA C22.2 No 107.1
 • EN/IEC62368-1
 • Holding Time : > 20 Ms 115 V A
 • > 40 Ms 230 V AC
 • Dielectric Strength : 3000 V Ac With Input To Output
 • Shock Resistance : 100 M/S² For 11 Ms
 • Environmental Characteristic : 3M4 Conforming To IEC 60721-3-3
 • Power Supply Type : Regulated Switch Mode
 • Current Consumption : < 2.5 A 115 V AC
 • < 1.4 A 230 V AC
 • < 1.3 A 140 V DC
 • Vibration Resistance : 3 mm (F= 2-9 Hz) Conforming To IEC 60068-2-6
 • 10 M/S² (F= 9-200 Hz) Conforming To IEC 60068-2-6
 • Supply : Selv Conforming To EN/IEC60950-1
 • Selv Conforming To EN/IEC60204-1
 • Selv Conforming To IEC 60364-4-41
 • Net Weight : 0.55 Kg
 • Maximum Leakage Current : 1 Ma 240 V AC
 • Output Protection Type : Against Overload And Short-Circuits, Protection Technology: Automatic Reset
 • Against Over Temperature, Protection Technology: Manual Reset
 • Against Overvoltage, Protection Technology: Manual Reset
 • Power Supply Output Current : 5 A
 • Output Voltage Limits : 22...28 V
 • Mounting Support : Top Hat Type Th35-15 Rail Conforming To IEC 60715
 • Top Hat Type Th35-7.5 Rail Conforming To IEC 60715
 • Double-Profile Din Rail
 • Response Time : < 1 S
 • Operating Altitude : < 5000 M
 • Electrical Shock Protection Class : Class I
 • Enclosure Material : Aluminium
 • Electromagnetic Emission : Conducted Emissions Conforming To EN 61000-6-3
 • Radiated Emissions Conforming To EN 61000-6-4
 • Range Of Product : Modicon Power Supply
 • Residual Ripple : < 120 Mv
 • Status Led : 1 Led (Green)Output Voltage
 • Product Certifications : CE
 • Cul Listed
 • Cul Recognized
 • RCM
 • CB Scheme
 • EAC
 • KC
 • Pollution Degree : 2
 • Earthing System : Tn
 • Tt
 • It
 • Electromagnetic Compatibility : Immunity To Electrostatic Discharge - Test Level: 6 Kv (Contact Discharge) Conforming To EN/IEC61000-4-2
 • Immunity To Electrostatic Discharge - Test Level: 9 Kv (Air Discharge) Conforming To EN/IEC61000-4-2
 • Immunity To Conducted Rf Disturbances - Test Level: 10 V/M (80 Mhz...2 Ghz) Conforming To EN/IEC61000-4-3
 • Immunity To Conducted Rf Disturbances - Test Level: 5 V/M (2...2.7 Ghz) Conforming To EN/IEC61000-4-3
 • Immunity To Conducted Rf Disturbances - Test Level: 3 V/M (2.7...6 Ghz) Conforming To EN/IEC61000-4-3
 • Immunity To Fast Transients - Test Level: 4 Kv (On Input-Output) Conforming To EN/IEC61000-4-4
 • Surge Immunity Test - Test Level: 3 Kv (Between Power Supply And Earth) Conforming To EN/IEC61000-4-5
 • Surge Immunity Test - Test Level: 1.5 Kv (Between Phases) Conforming To EN/IEC61000-4-5
 • Immunity To Conducted Rf Disturbances - Test Level: 10 V (0.15...80 Mhz) Conforming To EN/IEC61000-4-6
 • Immunity To Magnetic Fields - Test Level: 30 A/M (50...60 Hz) Conforming To EN/IEC61000-4-8
 • Immunity To Voltage Dips Conforming To EN/IEC61000-4-11
 • Disturbing Field Emission Conforming To En 55016-2-3
 • Limits For Harmonic Current Emissions Conforming To EN 61000-3-2
 • Conducted Disturbance Emission Conforming To En 55016-1-2
 • Conducted Disturbance Emission Conforming To En 55016-2-1
 • Connections - Terminals : Screw Connection: 0.5...4 mm², (Awg 20...Awg 12) Without Wire End Ferrule For Output
 • Screw Connection: 0.5...2.5 mm², (Awg 20...Awg 14) With Wire End Ferrule For Output
 • Screw Connection: 0.75...4 mm², (Awg 18...Awg 12) Without Wire End Ferrule For Input
 • Screw Connection: 0.75...4 mm², (Awg 18...Awg 12) With Wire End Ferrule For Input
 • Network Frequency Limits : 50-60 Hz
 • Variant Option : Optimized
 • IP Degree Of Protection : IP20
 • Input Protection Type : Integrated Fuse (Not Interchangeable) 4 A
 • External Protection (Recommended) 20 A Curve C
 • External Protection (Recommended) 13 A Curve C
 • Meantime Between Failure [Mtbf] : 700000 H At 25 °C, Full Load Conforming To Sr 332
 • Power Dissipation In W : 25 W
 • Service Life : 10 Year(S)
 • Rated Power In W : 120 W
 • Load Capacitance : 8000 µf
 • Efficiency : 85 % At 115 V AC
 • 88 % At 230 V AC
 • Inrush Current : 30.0 A At 115 V
 • 60.0 A At 230 V
 • Power Factor : 0.55 At 115 V AC
 • 0.45 At 230 V AC

Minimum sell quantity:

Order Quantity Multiple:

Catalogue Page Number: 17-79

Technical Specifications

Type Power Supply
Power Rating 120 W
Input Voltage 100...240 V AC single phase
100...240 V AC 2 phases
140...340 V DC
Height 123.6 mm
Depth 117.6 mm
Output Voltage 24 V DC
Width 40 mm
Customers Also Bought