Skip to content Skip to navigation menu
click to open Expanded view
Allen-Bradley Allen-Bradley (View All Products)

Allen-Bradley - NHP - Prox - SS-18 mm 10-30Vdc 8 mm Unshld No-NPN 3Wire DC-Micro-4 - 40 mm x 40 mm x 70 mm - 871TMDH8NN18D4

  • Allen-Bradley
  • BW#: 00351717
  • Mfr#: 871TMDH8NN18D4
  • UNSPSC#: 32151700
Login or Register to view price
QTY

Features
  • Inductive sensors provide reliable detection of metal objects

  • Ultrasonic sensors provide long distance sensing in applications unsuitable for a photoelectric sensor

  • Capacitive sensors provide optimum flexibility in level sensing applications

  • Available in a wide range of housings to suit everything from light-duty applications through to harsher washdown or welding applications


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

  • Service Information: Product is not repairable
  • Product Series: TemBreak 2 MCCB
  • Standards Compliance: IEC 60947-2, JIS C 8201-2-1 Ann.1, EN 60947-2, AS/NZS 60947-2, NEMA AB1
  • Certifications: CE, ASTA
  • Shipping Approvals: Contact NHP
  • Component Type MCCB: MCCB AC
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Adjustable Thermal Adjustable Magnetic
  • Im, Magnetic Trip Current, Max: 1250 A
  • Im, Magnetic Trip Current, Min: 750 A
  • In, Rated Current at 45°C: 125 A @45°C
  • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 25 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 22 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
  • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 55 % Icu
  • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 100 % Icu
  • Ir, Thermal Trip Current, Max: 125 A
  • Ir, Thermal Trip Current, Min: 80 A
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC: 85 kA @240VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 65 kA @400/415VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 50 kA @440VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 25 kA @525VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 40 kA @250VDC
  • Depth: 68 mm
  • Frame Size: 125 AF size
  • Rated Frequency: 50/60 Hz
  • Height: 155 mm
  • Number of Poles: 3
  • Poles: 3P
  • Electrical Service Life at Un, In: 30000 cycles
  • Mechanical Service Life: 30000 cycles
  • Magnetic Trip Type: Adjustable type
  • Thermal Trip Type: Adjustable type
  • Uimp, Impulse Withstand Voltage: 8 kV
  • Ui, Rated Insulation Voltage: 800 V (rms)
  • Ue, Rated Operational Voltage, AC, max: 690 V AC
  • Ue, Rated Operational Voltage, DC, max: 250 V DC
  • Weight: 1.1 kg
  • Width: 90 mm
  • Reverse Connection Of Supply Possible: Yes
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Length 65 mm
    Customers Also Bought
    Alternate Products