Skip to content Skip to navigation menu
click to open Expanded view
Allen-Bradley Allen-Bradley (View All Products)

Allen-Bradley 1931EFGE Overload Electronic E100 Advanced - For 100-C60/97 - 20-100A

  • Allen-Bradley
  • BW#: 02845141
  • Mfr#: 1931EFGE
  • UNSPSC#: 32151700
Login or Register to view price
QTY

Features
  • The E100 relay provides the following features:
  • Electronic overload detection
  • Test and reset buttons
  • Simple configuration
  • Auto (193/592-1EF only)/manual reset selection
  • Selectable trip class
  • RMS current sensing (50/60 Hz)
  • Adjustable trip current
  • External current transformer configurations
  • Integration with both IEC and NEMA contactors
  • Direct and pass-through mounting options


  • Specifications

     • Service Information: Product is not repairable
     • Product Series: TemBreak 2 MCCB
     • Standards Compliance: IEC 60947-2, EN 60947-2, JIS C 8201-2-1 Ann.1, AS/NZS 60947-2, NEMA AB1
     • Certifications: CE, ASTA
     • Shipping Approvals: Contact NHP
     • Component Type MCCB: MCCB AC
     • Standard Installation Method: Front Connection
     • Trip Unit Protection Type: Adjustable Thermal Adjustable Magnetic
     • Im, Magnetic Trip Current, Max: 756 A
     • Im, Magnetic Trip Current, Min: 378 A
     • In, Rated Current at 45°C: 63 A @45°C
     • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 25 kA
     • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 22 kA
     • Ics, Rated Service Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
     • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 100 % Icu
     • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 76 % Icu
     • Ir, Thermal Trip Current, Max: 63 A
     • Ir, Thermal Trip Current, Min: 40 A
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 240V AC: 50 kA @240VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 36 kA @400/415VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 25 kA @440VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 22 kA @525VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 690V AC: 6 kA @690VAC
     • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 250V DC: 25 kA @250VDC
     • Depth: 68 mm
     • Frame Size: 125 AF size
     • Rated Frequency: 50/60 Hz
     • Height: 155 mm
     • Number of Poles: 3
     • Poles: 3P
     • Electrical Service Life at Un, In: 30000 cycles
     • Mechanical Service Life: 30000 cycles
     • Magnetic Trip Type: Adjustable type
     • Thermal Trip Type: Adjustable type
     • Uimp, Impulse Withstand Voltage: 8 kV
     • Ui, Rated Insulation Voltage: 800 V (rms)
     • Ue, Rated Operational Voltage, AC, max: 690 V AC
     • Ue, Rated Operational Voltage, DC, max: 250 V DC
     • Weight: 1.1 kg
     • Width: 90 mm
     • Reverse Connection Of Supply Possible: Yes

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications