Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Please note, your account has been configured incorrectly, restricting your access to the website. Please contact your administrator or customer support on 13 73 23 for assistance.
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Endress+Hauser Endress+Hauser (View All Products)

Endress+Hauser FTL51B-56C0/0 Flow Switch - Liquiphant Vibronic Liquid Process - FTL51B-AAA2BBAAA3BJI1VCJ+Z1

  • Endress+Hauser
  • BW#: 02094064
  • Mfr#: Q:2013012113
  • UNSPSC#: 39122213
Login or Register to view price
QTY

Features
 • Point level switch for all liquid media:
The Liquiphant FTL51B is specialized for the process industry and already developed according to IEC 61508 to be used directly in SIL2 and SIL3 applications without big efforts
You conduct periodic proof tests according to SIL or WHG simply mobile with an intuitive wizard. At the end you receive an automated documentation
Liquiphant measures reliably and is not affected by changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up
 • Universal measuring principle for limit detection – proven vibronic technology
 • Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)
 • Periodic proof testing is quickly and simple organized with guided wizards via the SmartBlue-App or via a test button or magnetic pin from outside. Via these ways, you can initiate the instrument for a fast and easy testing of the safety loop
 • Heartbeat Technology allows safe, continuous diagnostics and a simple verification
 • Heartbeat Diagnostics:
Permanent diagnostics increase the safety of the plant
You connect your device via the SmartBlue-App and you easily have real time diagnostics at hand
 • Heartbeat Verification:
The device can be verified without process interruption
The verification report is generated automatically
 • Heartbeat Monitoring:
With the frequency tracking of the sensor data you have all information at hand for predictive maintenance and process optimization strategies

Applications
 • The Liquiphant FTL51B is specialized for the
process industry and already developed according to IEC 61508 to be
used directly in SIL2 and SIL3 applications without big efforts
 • You conduct periodic proof tests according to SIL or WHG simply mobile with
an intuitive wizard. At the end you receive an automated documentation
 •Liquiphant measures reliably and is not affected by changing media properties,
flow, turbulences, gas bubbles, foam, vibrations or build-up

Specifications

 • Instrument No: 4331FS0910
 • Instrument Title: Bypass Slag Launder Jacket Water Return Flow Switch
 • Functional Description: ODE4331-FDE-0907
 • TAG NUMBER: 4331FS0910
 • SERVICE: Bypass Launder Jacket Water Return Flow
 • EQUIPMENT / VESSEL NUMBER: 4331-150-3-JW-0279
 • FLANGE RATING / FINISH: N/A
 • AREA CLASSIFICATION: Non-Hazardous
 • P & ID: ODE4301-PR-1358
 • BHP BILLITON STANDARD SPECIFICATION - STSP No. ODE0000-STSP-0016

 • Instrument No: 4331FS0909
 • Instrument Title: Bypass Slag Launder Jacket Water Return Flow Switch
 • Functional Description: ODE4331-FDE-0907
 • TAG NUMBER: 4331FS0909
 • SERVICE: Bypass Launder Jacket Water Return Flow
 • EQUIPMENT / VESSEL NUMBER: 4321-150-3-JW-0277
 • FLANGE RATING / FINISH: N/A
 • AREA CLASSIFICATION: Non-Hazardous
 • P & ID: ODE4301-PR-1358
 • BHP BILLITON STANDARD SPECIFICATION - STSP No. ODE0000-STSP-0016

 • Liquiphant FTL51B 1 ST - FTL51B-AAA2BBAAA3BJI1VCJ+Z1
 • 010 Approval: - (AA) Non-hazardous area
 • 020 Output: - A2 FEL62, 3-wire PNP 10-55VDC + test button
 • 030 Display Operation: - B LED module outside visible; switch
 • 040 Housing Material: - B Single compartment; Alu, coated
 • 050 Electrical Connection: - A Gland M20, plastic, IP66/68 NEMA Type 4X/6P
 • 060 Application: A Process max 150oC/302oF, max 64bar - A Process max 150oC/302oF, max 64bar
 • 080 Surface Refinement: A Standard Ra<3,2um/126uin - A Standard Ra<3,2um/126uin
 • 085 Type Of Probe: - 3 Short tube version
 • 090 Sensor Length; Material: BJ Short tube version; 316L - BJ Short tube version; 316L
 • 105 Process Connection, Sealing Surface: - I1 Thread ISO228, G
 • 110 Process Connection: - VCJ 1", 316L
 • 895 >>Marking: - Z1 Tagging (TAG), see additional spec

Minimum sell quantity:

Order Quantity Multiple:

Technical Specifications

Type Float Switch
Operator Type Web_ProductName_on_Part
Material Plastic
Colour Blue/Grey
Air temperature for operation -60 °C...+70 °C
Customers Also Bought